IBM Support

PH35127: ABEND0C4 OCCURRED WHEN THE CATALOG MANAGER PROCESSES GSAMS IN THE IMS DIRECTORY

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The Catalog Manager utility may cause ABEND0C4 when it processes
    a GSAM DBD in the IMS directory and a GSAM DBD is populated
    with some condition. When the GSAM DBD is populated to the IMS
    directory, the IMS Catalog Populate utility uses a GSAM DBD in a
     DBDLIB. If the GSAM DBD in the DBDLIB is generated in IMS V11
    or earlier IMS version, the Catalog Manager utility may cause
    ABEND. The structure of GSAM DBD in DBDLIB which is generated in
     IMS V11 or earlier version is different from GSAM DBD which is
    generated in IMS V12 or later. The Catalog Manager missed to
    check the structure and it causes ABEND.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMS Library Integrity Utilities for z/OS,    *
    *                 Version 2 Release 2 (FMID=H27P220) users     *
    *                 who use the Catalog Manager utility.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND0C4 occurred when the Catalog      *
    *                      Manager utility compared a GSAM DBD in  *
    *                      the IMS directory and original GSAM DBD *
    *                      which was used to create IMS directory  *
    *                      was generated by IMS V1.2 or earlier    *
    *                      version.                                *
    *                      ABEND0C4 also may occur when the        *
    *                      Catalog Manager utility decodes a       *
    *                      GSAM DBD in the IMS directory and       *
    *                      original GSAM DBD which was used to     *
    *                      create IMS directory was generated by   *
    *                      IMS V11 or earlier version.             *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR fixes the Catalog Manager utility not to cause
    ABEND0C4 when it compares or converts a GSAM DBD in the IMS
    directory and GSAM DBD was generated in some condition.
    
    Though DBD generated by IMS V1.3 or later has the section
    DBDXTAB, DBD generated by IMS V1.2 or earlier version does not
    have the section.
    Also, though DBD generated by IMS V12 or later has the section
    DXVECTAB, DBD generated by IMS V11 or earlier version does not
    have the section.
    
    GSAM DBD created in the IMS directory has same structure as GSAM
    DBD in a DBDLIB. So the Catalog Manager utility should skip
    these section when it compares or converts such a GSAM DBD in
    the IMS directory.
    
    This APAR fixed the Catalog Manager utility not to access
    DBDXTAB or DXVECTAB when it processes a GSAM DBD in the IMS
    directory and the GSAM DBD was populated with a GSAM DBD which
    was generated by earlier IMS version.
    

Problem conclusion

  • The following modules have been changed to fix the above
    problem:
     FABXCATM,FABLACB0,FABLADP0,FABNACB0
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH35127

  • Reported component name

    IMS LIBR INTEG

  • Reported component ID

    5655I4200

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-03-09

  • Closed date

    2021-03-23

  • Last modified date

    2022-09-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI74548

Modules/Macros

  • FABLACB0 FABLADP0 FABNACB0 FABXCATM
    

Fix information

  • Fixed component name

    IMS LIBR INTEG

  • Fixed component ID

    5655I4200

Applicable component levels

  • R220 PSY UI74548

       UP21/03/24 P F103

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]

Document Information

Modified date: