A fix is available
APAR status
Closed as program error.
Error description
When running load job of the SMFV_07914_SMF79HDR, field SMF79GIE cause a failure with invalid data: HLOU5807W - Column SMF79GIE has invalid data in Record=1 PART=0 IGNORE BELOW DURING APAR CREATION: Getting the following errors on field SMF79GIE when running Load job. HLOU5807W 054 12:27:24.66 Column SMF79GIE has invalid data in Record=1 PART=0 HLOU5807W 054 12:27:24.66 Column SMF79GIE has invalid data in Record=1 PART=0 HLOU5807W 054 12:27:24.66 Column SMF79GIE has invalid data in Record=1 PART=0 HLOU5807W 054 12:27:24.66 Column SMF79GIE has invalid data in Record=1 PART=0 SMF79GIE is defined in our SMF Map as Timestamp but it looks like we are not converting it correctly. Here is what is being returned when running the following query on RS28/HLV2: SELECT SMF79GIE FROM SMFV_07914_SMF79HDR__CSD_SUPPORT_JL_T4921635_JAN27_RMFOUT SMF79GIE 0002-11-30 00:00:00.0 0002-11-30 00:00:00.0 0002-11-30 00:00:00.0 0002-11-30 00:00:00.0 0002-11-30 00:00:00.0 0002-11-30 00:00:00.0 0002-11-30 00:00:00.0 0002-11-30 00:00:00.0 0002-11-30 00:00:00.0 SMF79GIE define: |80|50|SMF79GIE|8|binary|Projected gathering interval end (STCK format) GMT time.|
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: ALL USERS * **************************************************************** * PROBLEM DESCRIPTION: Fail with error loading several * * SMF_79* virtual tables with RMF data * **************************************************************** * RECOMMENDATION: APPLY PTF * **************************************************************** Fail with error loading several SMF_79* virtual tables with RMF data
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PH35013
Reported component name
IDAA LOADER DAT
Reported component ID
5639OLE01
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-03-03
Closed date
2021-04-06
Last modified date
2021-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
HLV$4FEE HLV$4FEM HLV$741E HLV$741M HLV$IA40 HLV$IA42 HLV$IAL1 HLV$IAO1 HLV$KE32 HLV$KE33 HLV$KFE1 HLV$MEP0 HLV$N830 HLV$N850 HLV$N860 HLV$N870 HLV$N880 HLVCADRD HLVCTGRD HLVCTSRD HLVCTVRD HLVCTZRD HLVOBRTV HLVSQ29D HLVSQ29N HLVSQ2AD HLVSQ2AN HLVSQ2BD HLVSQ2BN HLVSQ2CD HLVSQ2CN HLVSQ2DD HLVSQ2DN HLVSQL9D HLVSQL9N HLVSQLAD HLVSQLAN HLVSQLBD HLVSQLBN HLVSQLCD HLVSQLCN HLVSQLDD HLVSQLDN
Fix information
Fixed component name
IDAA LOADER DAT
Fixed component ID
5639OLE01
Applicable component levels
R210 PSY UI74789
UP21/04/08 P F104
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]
Document Information
Modified date:
04 May 2021