Error description

  • Db2 Object Compare: Basic triggers with SYSTEM_TIME
    SENSITIVE, BUSINESS_TIME SENSITIVE, ARCHIVE SENSITIVE set to NO
    
    When a basic trigger is created in DB2 z/OS V12, the three
    parameters, SYSTEM_TIME SENSITIVE, BUSINESS_TIME SENSITIVE, and
    ARCHIVE SENSITIVE are set to YES for the trigger package.  The
    is no option to set them to NO with the CREATE TRIGGER (basic)
    
    During a compare messages like this may be seen:
    
    Compare Trigger source(A.TRIGGER1)
    and target(A.TRIGGER1)
      Source type : Basic  Target type : Basic
        (A)Field SYSTEM_TIME SENSITIVE changed from YES to NO
        (A)Field BUSINESS_TIME SENSITIVE changed from YES to NO
        (A)Field ARCHIVE SENSITIVE changed from YES to NO
      Trigger will be altered
    
    However, the trigger still ends up with them set to YES.
    

Local fix

  • A REBIND TRIGGER PACKAGE can be used to set the parameters to
    no.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Db2 Object Comparison Tool for      *
    *                 z/OS.                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: Informational message ADB7389I          *
    *                      is changed to a warning message.        *
    ****************************************************************
    Compare currently uses ADB7389I as an
    informational message. This message will
    be updated to a warning message and will
    then be seen in the tool and documentation
    as ADB7389W.
    
    For example, this message
    
    Compare Trigger source <trigger name> and target <trigger name>
      Source type : Basic  Target type : Basic
        (A)Field SYSTEM_TIME SENSITIVE changed from YES to NO
        (A)Field BUSINESS_TIME SENSITIVE changed from YES to NO
        (A)Field ARCHIVE SENSITIVE changed from YES to NO
      Trigger will be altered
    
    Would cause an informational message ADB7389I before this apar.
    This message has been changed
    to a warning.
    

Problem conclusion

  • The problems have been resolved.
    Search Keywords: MSGADB7389I, MSGADB7389W
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH34842

  • Reported component name

    DB2 ADMIN TOOL

  • Reported component ID

    568851500

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-02-25

  • Closed date

    2021-06-03

  • Last modified date

    2021-07-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI75676

Modules/Macros

  • ADB7000
    

Fix information

  • Fixed component name

    DB2 ADMIN TOOL

  • Fixed component ID

    568851500

Applicable component levels

  • RC10 PSY UI75676

       UP21/07/02 P F106

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.