Error description
If S-TAP or QM is cancelled immediately after startup (e.g. within 5 seconds,) the common collector can reference the prior incidence of S-TAP/QM
Local fix
The workaround is not to cancel the started task until it's fully initialized
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM Db2 Query Monitor for z/OS * * Users of IBM Security Guardium S-TAP for * * Db2 on z/OS * **************************************************************** * PROBLEM DESCRIPTION: HCQC110 DB2 COMMON ACCESS COLLECTOR * * MONITORING AGENT DE-INSTALL FAILURE * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** ABEND DC2-0F9 in CQC#REST when attempting to detach a memory object that was not allocated due to an early termination of the Query Monitor or Security Guardium S-TAP initialization process.
Problem conclusion
If Query Monitor or Security Guardium S-TAP were cancelled immediately after startup, the next start picked up references to the prior instance of Query Monitor or Security Guardium S-TAP. The logic was corrected to avoid picking up memory references from prior executions. Search Keywords: ABENDS DC2-0F9 CQC#REST
Temporary fix
Comments
APAR Information
APAR number
PH34669
Reported component name
COMMON COLLECTO
Reported component ID
5639OLC00
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-02-19
Closed date
2021-04-28
Last modified date
2021-06-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CQC#REST CQCMALOX CQCMB2B1 CQCMB2C5 CQCMB3B1 CQCMB3C5 CQCMB4B1 CQCMB4C5 CQCMBNB1 CQCMBNC5 CQCMHST9 CQCMINSD CQCMINST CQCMSCLN CQCMSCLS CQCTK1B1 CQCTK1C5 CQCTK2B1 CQCTK2C5 CQCTK3B1 CQCTK3C5 CQCTK4B1 CQCTK4C5 CQCTK5B1 CQCTK5C5 CQCTK6B1 CQCTK6C5 CQCTK9B1 CQCTK9C5 CQCTTEX1
Fix information
Fixed component name
COMMON COLLECTO
Fixed component ID
5639OLC00
Applicable component levels
R110 PSY UI75144
UP21/05/04 P F105
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0"}]
Document Information
Modified date:
03 June 2021