A fix is available
APAR status
Closed as program error.
Error description
Running a Cross System Work report, you receive an abends0c4 in module CPALSXMF + x'1FEA'. Just prior to the abend, the following messages were generated. CPA0230I Dictionary Record default is being used, APPLID=applid , Release= 6.9.0 CPA0359W Connector ID X'0177' not mapped by Performance Dictionary record from module CPADICM_/CPAPRSMF Field ID=User field , APPLID=applid , Release= 6.9.0 from module CPADICM_/CPAPRSMF CPA0311E Field ID field is not defined to Dictionary - field ignored from module CPALSXMF/CPALSXMF CPA0329E Dictionary returned error on Field ID field from module CPALSXMF/UOWPA The abend is due to the field area being too short to accommodate a user field longer the 256 bytes. This APAR is being created for case TS004500171. Additional Keywords and Symptoms: KIXREVRJL
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of CICS PA V5.4 * **************************************************************** * PROBLEM DESCRIPTION: Abend0C4 in CPALSXMF when specifying a * * User Field longer than 256 bytes. * **************************************************************** An S0C4 abend can occur in module CPALSXMF +x'1FEA' or +x'2216' when a user field longer than 256 bytes in specified in the FIELDS operand. The 0C4 abend is due to the field area length being defined as 256 bytes, causing storage to be overwritten when a field that is longer than 256 bytes is moved into it.
Problem conclusion
This APAR increases the field area length to be the user field maximum length of 8192 bytes.
Temporary fix
Comments
APAR Information
APAR number
PH34580
Reported component name
CICS PERF ANALY
Reported component ID
5655Y2300
Reported release
540
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-02-17
Closed date
2021-03-02
Last modified date
2021-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI74216
Modules/Macros
CPALSXMF
Fix information
Fixed component name
CICS PERF ANALY
Fixed component ID
5655Y2300
Applicable component levels
R540 PSY UI74216
UP21/03/06 P F103
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.