A fix is available
APAR status
Closed as program error.
Error description
If Db2 encounters an abnormally shutdown and then restarts, CDC may issue message CHC1528E to indicate an UR Control Record sequencing error has been detected, Record subtype = NDTDO, Record subtype set indicators = X'0000080B'
Local fix
No
Problem summary
**************************************************************** * USERS AFFECTED: Users of IIDR CDC for z/OS * **************************************************************** * PROBLEM DESCRIPTION: After applying PTF UI72338, CDC handles * * in-doubt URs properly, however if Db2 * * suffers at least one failure before the * * in-doubt UR is resolved, CDC may still * * issue message CHC1528E with Record * * subtype = NDTDO and Record subtype set * * indicators =X'0000080B'. * **************************************************************** * RECOMMENDATION: APPLY CORRECTIVE SERVICE * **************************************************************** Message CHC1528E may be issued if Db2 restarts from a previous abnormal shutdown, after which the subscription ends in error.
Problem conclusion
Modified the UR Control Records validation logic to be able to process multiple END TODO log records in the same UR.
Temporary fix
Comments
APAR Information
APAR number
PH34307
Reported component name
INFO SRVR CDC Z
Reported component ID
5655U7600
Reported release
A21
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-02-09
Closed date
2021-03-01
Last modified date
2021-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
010PC2 UI74183 010PC2
Modules/Macros
CHCSTGSP
Fix information
Fixed component name
INFO SRVR CDC Z
Fixed component ID
5655U7600
Applicable component levels
RA21 PSY UI74183
UP21/03/05 P F103
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.