A fix is available
APAR status
Closed as program error.
Error description
The calculated MSU consumption does not allow for accurate Tailored Fit Pricing consumption usage reporting.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of the Capacity Planning for * * z/OS Component of IBM Z Performance * * and Capacity Analytics. * **************************************************************** * PROBLEM DESCRIPTION: The calculated MSU consumption does * * not allow for accurate Tailored Fit * * Pricing consumption usage reporting. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** Calculated MSUs consumed are based on logical processor dispatch time, instead of logical processor effective dispatch time, which results in higher than expected MSUs consumed.
Problem conclusion
The calculation of the number of consumed MSUs is changed to use logical processor effective dispatch time (SFM70EDT), instead of logical processor dispatch time (SMF70PDT). This impacts the following columns: NUM_CONSUMED_MSU of table CP_CPU_LPAR_T NUM_CONSUMED_MSU of table CP_CPU_LPAR_H NUM_CONSUM_MSU of table CP_CPU_LPAR_D NUM_CONSUM_MSU of table CP_CPU_LPAR_W NUM_CONSUM_MSU of table CP_CPU_LPAR_M NUM_CONSUM_MSU of table CP_CPU_LPAR_F NUM_CONSUM_MSU of table CP_CPU_CEC_F The Capacity Planning manual is updated to reflect these changes.
Temporary fix
Comments
APAR Information
APAR number
PH33998
Reported component name
TDS FOR Z/OS
Reported component ID
569510100
Reported release
C01
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-01-31
Closed date
2021-02-17
Last modified date
2021-03-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI74005
Modules/Macros
DRLTCPCL
Fix information
Fixed component name
TDS FOR Z/OS
Fixed component ID
569510100
Applicable component levels
RCA8 PSY UI74005
UP21/02/19 P F102
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2DUM","label":"IBM Z Decision Support"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C01"}]
Document Information
Modified date: