A fix is available
APAR status
Closed as program error.
Error description
CASE TS004597935: First digit is zero when Binary moved to alpha field Date opened: 2020-12-01 PTF Pre-reqs: UI73401 APAR Pre-reqs: none Severity: High -------- Users Affected: ------------- All IMU V4.1 Problem Description ------------------- Client reported that receiving alphanumeric field contains zero in the high order byte when a binary (BL2) is assigned to an alpha field. Example: TESTBL2 W 2 B VALUE X'7FFF' TESTALF 2 5 A TESTALF = TESTBL2 Results in: '02767' It should be: 32767' Problem Summation ----------------- The process of assigning binary fields to alpha fields is artificially controlled by IMU. When assigning BL2 or BL4 to an alpha field, IMU limits the number of digits moved into alpha field as follows: 1. Four(4) digits for BL2 2. Nine(9) digits for BL4 thus causing one (1) byte truncation. The work-around is to change the alpha field to a display numeric field. i.e., TESTALF 2 5 N Note: Assigning binary field to a display numeric field works properly. Problem Conclusion: ------------------ IMU was changed to increase capacity of intermediate value to: a) Five(5) bytes for BL2 fields b) Ten(10) bytes for BL4 fields. The adjustment is applied when binary fields are assigned to Alpha fields. The adjustment is not applied when binary fields are assigned to DISPLAY numeric fields. Changed modules: --------------- FSOFT01.V4R1M0.SFSYFJCC EASYT007 - CCL1 byte code module Special Installation Instructions: --------------------------------- There is no impact on existing Easytrieve Plus programs that do not contain errors related to this APAR. Action: ------ 1. Apply PTF UI73401. 2. Apply this APAR. 3. Translate and run the failing Easytrieve Plus programs. ----------------------------------------------------------------
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All IMU V4.1 * **************************************************************** * PROBLEM DESCRIPTION: Client reported that receiving * * alphanumeric field contains zero in the * * high order byte when a binary (BL2) is * * assigned to an alpha field. * * * * Example: * * TESTBL2 W 2 B VALUE X'7FFF' * * TESTALF 2 5 A * * * * TESTALF = TESTBL2 * * * * Results in: '02767' * * * * It should be: 32767' * **************************************************************** The process of assigning binary fields to alpha fields is artificially controlled by IMU. When assigning BL2 or BL4 to an alpha field, IMU limits the number of digits moved into alpha field as follows: 1. Four(4) digits for BL2 2. Nine(9) digits for BL4 thus causing one (1) byte truncation. The work-around is to change the alpha field to a display numeric field. i.e., TESTALF 2 5 N Note: Assigning binary field to a display numeric field works properly.
Problem conclusion
IMU was changed to increase capacity of intermediate value to: a) Five(5) bytes for BL2 fields b) Ten(10) bytes for BL4 fields. The adjustment is applied when binary fields are assigned to Alpha fields. The adjustment is not applied when binary fields are assigned to DISPLAY numeric fields.
Temporary fix
Comments
APAR Information
APAR number
PH33293
Reported component name
MIGRATION UTILI
Reported component ID
5697N4400
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-01-13
Closed date
2021-02-09
Last modified date
2021-03-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI73875 PH36895
Modules/Macros
FSYET007
Fix information
Fixed component name
MIGRATION UTILI
Fixed component ID
5697N4400
Applicable component levels
R410 PSY UI73875
UP21/02/16 P F102
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.