A fix is available
APAR status
Closed as program error.
Error description
The UID specified in the PARM attribute of the Db2 HPU EXEC CARD is unduly ignored when the following conditions are fulfilled: - the UID specified in the EXEC CARD is 1 character long - another option is specified in the PARM attribute, after the UID option Db2 HPU behaves as if no UID was specified and uses the default value which can lead to unpredictable issues involving: - the concurrency of Db2 HPU steps - the RESTART feature
Local fix
none but as specifying a very short UID value is not advisable as it does not allow a fine tuning of the value that determines the capabilities of concurrency between jobs, consider specifying a longer UID value,
Problem summary
**************************************************************** * USERS AFFECTED: Users of Db2 High Performance Unload * * for z/OS * **************************************************************** * PROBLEM DESCRIPTION: The UID specified in the PARM attribute * * of the Db2 HPU EXEC CARD is unduly * * ignored when the following conditions * * are fulfilled: * * - the UID specified in the EXEC CARD is * * 1 character long * * - another option is specified in the * * PARM attribute, after the UID option * * * * Db2 HPU behaves as if no UID was * * specified and uses the default value * * which can lead to unpredictable issues * * involving: * * - the concurrency of Db2 HPU steps * * - the RESTART feature * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** Default UID unduly used if explicit UID is one character long
Problem conclusion
Code has been changed to fix this problem
Temporary fix
Comments
APAR Information
APAR number
PH33075
Reported component name
DB2 HI PERF UNL
Reported component ID
5697F4400
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-01-05
Closed date
2021-02-08
Last modified date
2021-03-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
INZ$$PRM INZA30 INZA40 INZB601E INZB601I INZB61 INZB70E INZB70I INZBIND INZCHECK INZCRXSM INZCRXSQ INZHPUCL INZSDN INZTDSC INZTPMEM INZTVAR INZUTIB1 INZUTIB2 INZUTILC INZUTILK INZUTILL
Fix information
Fixed component name
DB2 HI PERF UNL
Fixed component ID
5697F4400
Applicable component levels
R510 PSY UI73856
UP21/02/24 P F102
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0"}]
Document Information
Modified date: