IBM Support

PH32854: DB2 ADMIN: U.UL ON HISTORY TABLE, TYPE=H, GETTING INVALID OBJECT TYPE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Db2 Admin: U.UL on History Table, TYPE=H, getting Invalid
    Object Type.  This also occurs if the UTIL command is used
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of the Db2 Administration Tool for     *
    *                 z/OS.                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: An invalid object type error occurred   *
    *                      on panel ADB21T when issuing the U.UL   *
    *                      line command on a history table.        *
    ****************************************************************
    Issuing the U.UL line command on panel ADB21T for a history
    table causes an invalid object type message. All table
    utilities and the U.BP and U.TU line commands should be
    allowed for history tables. Also, issuing UTIL on the history
    table and issuing the commands on the panel ADB2UT should be
    allowed.
    

Problem conclusion

  • The problems have been resolved.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH32854

  • Reported component name

    DB2 ADMIN TOOL

  • Reported component ID

    568851500

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-12-21

  • Closed date

    2021-04-02

  • Last modified date

    2021-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI74742

Modules/Macros

  • ADB21T   ADB2U
    

Fix information

  • Fixed component name

    DB2 ADMIN TOOL

  • Fixed component ID

    568851500

Applicable component levels

  • RC10 PSY UI74742

       UP21/04/06 P F104

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"12.1.0"}]

Document Information

Modified date:
04 May 2021