A fix is available
APAR status
Closed as program error.
Error description
ISSUE 1 - CHECK DATA utility requires a tablespace name when including an exception table - which becomes problematic, since Db2 V12 FL504 deprecated Non-UTS tablespaces. This means that only a single table can be defined per tablespace. Automation Tool should allow Db2 to create a new tablespace (and the related exception table) instead of creating a new exception table on an existing tablespace. ISSUE 2 - Program HAA@BSQL is not generating long table names correctly in the JCL. This problem occurs when a tablespace, which contains a table with a long name (greater than 38 bytes), is specified for the )IF TABLE NAME NOT _EXISTS clause in the generated JCL.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Users * **************************************************************** * PROBLEM DESCRIPTION: ISSUE 1 - CHECK DATA utility requires a * * tablespace name when including an * * exception table - which becomes * * problematic, since Db2 V12 FL504 * * deprecated Non-UTS tablespaces. This * * means that only a single table can be * * defined per tablespace. * * * * Automation Tool should allow Db2 to * * create a new tablespace (and the * * related exception table) instead of * * creating a new exception table on * * an existing tablespace. * * * * ISSUE 2 - Program HAA@BSQL is not * * generating long table names correctly * * in the JCL. This problem occurs when a * * tablespace - which contains a table * * with a long name (greater than 38 * * bytes) - is specified for the * * )IF TABLE NAME NOT_EXISTS clause in * * the generated JCL. * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** .
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PH31836
Reported component name
DB2 AUTOMATION
Reported component ID
5697G6300
Reported release
430
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-11-18
Closed date
2021-02-02
Last modified date
2021-03-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
HAA#IXP7 HAA$BUT2 HAA$BUTC HAA$BUTI HAA$BUTR HAA$BUTY HAA$DSFT HAA$UCHX HAAEXCTC HAAHUCHX
Fix information
Fixed component name
DB2 AUTOMATION
Fixed component ID
5697G6300
Applicable component levels
R430 PSY UI73747
UP21/02/04 P F102
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.0"}]
Document Information
Modified date:
06 March 2021