IBM Support

PH31302: RPP 970 A SQL ORDER ON ONE LINE DOESN'T GENERATE THE END-EXEC ON THE NEXT LINE (IF IN GENERATED LINE...)

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • in Rational Programming Patterns - v9.7.0, as a user writes an
    SQL order in RPP, the END-EXEC is automatically generated if the
    line holding the END-EXEC is a generated line (Macro line or
    Micro-Pattern generated for instance).
    This does not work if the SQL order is on a specific line (and
    followed by a Macro line for instance).
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users taht want to use SQL micro pattern in one line only    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * If the generated code contains only one line and the context *
    * is on a generted line, the END EXEC is not automatically     *
    * processed .                                                  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH31302

  • Reported component name

    RATL PROG PATTE

  • Reported component ID

    5725H0300

  • Reported release

    970

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-11-05

  • Closed date

    2020-12-01

  • Last modified date

    2020-12-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • R850 PSN

       UP

  • R900 PSN

       UP

  • R901 PSN

       UP

  • R910 PSN

       UP

  • R911 PSN

       UP

  • R912 PSN

       UP

  • R950 PSN

       UP

  • R951 PSN

       UP

  • R960 PSY

       UP

  • R961 PSY

       UP

  • R962 PSY

       UP

  • R970 PSY

       UP

  • R971 PSY

       UP