PH30311: LOAD API CAN GET ABENDS0C4 WHEN THE INIT OPTION IS SPECIFIED FORTHE COMPRESSION ROUTINE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND0C4 may occur when all of the following conditions are met:
    - Using Load API.
    - Multiple DBPCBs are defined in the PSB and the DBPCB for the
      second and subsequent HALDBs as the DBPCB used by HP Load.
    - There are segments with segment edit/compression routine
      specified with the INIT option on the first DBPCB and the
      DBPCB for HP Load.
    - The application program issues an ISRT call to the HP Load
      DBPCB first.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM IMS High Performance Load   *
    *                 for z/OS Version 2 Release 1 (FMID=H1IM210). *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND0C4 may occur when all of the      *
    *                      following conditions are met:           *
    *                      - Using Load API.                       *
    *                      - Multiple DBPCBs are defined in the    *
    *                        PSB and the DBPCB for the second and  *
    *                        subsequent HALDBs as the DBPCB used   *
    *                        by HP Load.                           *
    *                      - There are segments with segment       *
    *                        edit/compression routine specified    *
    *                        with the INIT option on the first     *
    *                        DBPCB and the DBPCB for HP Load.      *
    *                      - The application program issues an     *
    *                        ISRT call to the HP Load DBPCB first. *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    ABEND0C4 may occur when all of the following conditions are met:
    - Using Load API.
    - Multiple DBPCBs are defined in the PSB and the DBPCB for the
      second and subsequent HALDBs as the DBPCB used by HP Load.
    - There are segments with segment edit/compression routine
      specified with the INIT option on the first DBPCB and the
      DBPCB for HP Load.
    - The application program issues an ISRT call to the HP Load
      DBPCB first.
    HP Load mistakenly sets the address of the segment
    edit/compression routine in the IMS control block for a DBPCB
    other than the DBPCB for HP Load.
    

Problem conclusion

  • HP Load has been modified to sets the address of the segment
    edit/compression routine in the IMS control block correctly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH30311

  • Reported component name

    IMS HP LOAD

  • Reported component ID

    5655E0700

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-10-07

  • Closed date

    2020-10-19

  • Last modified date

    2022-09-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI72126

Modules/Macros

  • HPSRHAL2 HPSRHAL3 HPSRHAL4 HPSRHAL5 HPSRHAL7 HPSRHAL8 HPSRHAL9
    HPSRHALA HPSRHALB
    

Fix information

  • Fixed component name

    IMS HP LOAD

  • Fixed component ID

    5655E0700

Applicable component levels

  • R210 PSY UI72126

       UP20/10/21 P F010

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89F","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]

Document Information

Modified date:
08 September 2022