A fix is available
APAR status
Closed as program error.
Error description
Maximum I/O times are correct, but the timestamps that should match those values are incorrect. Also, timestamps are adjusted for Timezone offset, but not Leap Second offset. These issues will be corrected in this APAR.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Performance Analyzer V4.4 * **************************************************************** * PROBLEM DESCRIPTION: Incorrect data in IRUR Logger Report * **************************************************************** 1. Maximum I/O times are correct, but the timestamps that should match those values are incorrect. 2. Timestamps are adjusted for Timezone offset, but not Leap Second offset.
Problem conclusion
1. Max I/O timestamps are corrected to reflect the time of the Max I/O value. 2. Timestamps are adjusted for both TZO and LSO values from the IMS x'4500' record. 3. Several other issues addressed, including: Latch statistics were not correctly initialized, resulting in some incorrect values. TCB statistics percentage value calculations corrected. Some very large numbers were incorrectly formatted leading to overflows or incorrect results, which are now corrected. Sundry formatting corrections.
Temporary fix
Comments
APAR Information
APAR number
PH30014
Reported component name
IMS PERF ANALYZ
Reported component ID
5655E1500
Reported release
440
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-09-29
Closed date
2020-10-22
Last modified date
2020-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI72202
Modules/Macros
IPISAPAR IPISIRUR
Fix information
Fixed component name
IMS PERF ANALYZ
Fixed component ID
5655E1500
Applicable component levels
R440 PSY UI72202
UP20/10/27 P F010
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Performance Analyzer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"440"}]
Document Information
Modified date: