PH29957: IMS OPERATION MANAGER GETS ABENDS378-24 FROM GJEOMOP0

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IMS Operation Manager address space with Sysplex Manager can
    cause ABENDS378-24 in GJEOMOP0.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS Sysplex manager.            *
    ****************************************************************
    * PROBLEM DESCRIPTION: IMS Operation Manager address space     *
    *                      with Sysplex Manager can cause          *
    *                      ABENDS378-24 in GJEOMOP0.               *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF that corrects this APAR.       *
    ****************************************************************
    OM output user exit (GJEOMOP0) uses an internal buffer to send
    the command response text to SM Server. When the command
    response from OM contains a large number of lines of text lines,
    the storage area immediately following the internal buffer can
    be corrupted due to a logic error. This can break the control
    block for SM resources and cause ABENDS378-24 during SM
    resource clean up process.
    

Problem conclusion

  • GJEOMOP0 has been modified so that it does not break the storage
    area immediately following the internal buffer for the command
    response text.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH29957

  • Reported component name

    IMS SYSPLEX MGR

  • Reported component ID

    5655P0100

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-09-28

  • Closed date

    2020-10-22

  • Last modified date

    2020-11-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI72197

Modules/Macros

  • GJEOMOP0
    

Fix information

  • Fixed component name

    IMS SYSPLEX MGR

  • Fixed component ID

    5655P0100

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8AA","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.3.0"}]

Document Information

Modified date:
24 June 2022