IBM Support

PH29956: STORED PROCEDURES MAY FAIL WITH MSG "AQT20111E OPERATION RECEIVE...COULD NOT BE COMPLETED WITHIN THE TIME ALLOTTED (10 SECONDS)"

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as documentation error.

Error description

  • Stored Procedures may suddenly fail with message
    "AQT20111E Operation RECEIVE which was supposed to transfer 6
     bytes on TCP/IP socket 1 to the remote machine at IP address
     aa.bbb.cc.dd and port xxxx could not be completed within the
     time allotted (10 seconds)".
    Upon a next call of the stored procedure the error may be gone.
    
    Additional keywords:
    TS004186105 TS004188006 TS004224555 TS003860794
    GH#...IDAA-Server/issues/3231
    

Local fix

  • Add parameter "AQT_DRDA_TIMEOUT=300000" (300.000 milliseconds =
    300 seconds = 5 minutes) to member AQTENV and REFRESH your WLM
    SP address space.
    

Problem summary

  • Problem Summary:
    Loading accelerator-shadow tables in parallel may fail with
    message AQO2011E.
    
    Users affected:
    Customers using Db2 Analytics Accelerator Loader or using
    Stored Procedure ACCEL_LOAD_TABLES to load accelerator-shadow
    tables.
    
    Problem Scenario / Problem Symptoms:
    Using DB2 Analytics Accelerator Loader to load several
    accelerator-shadow tables in parallel my lead to a hang
    situation. The issue is accompanied by error message
    "AQT20111E Operation RECEIVE which was supposed to transfer 6
     bytes on TCP/IP socket 1 to the remote machine at IP address
     aa.bbb.cc.dd and port xxxx could not be completed within the
     time allotted (10 seconds)".
    

Problem conclusion

  • The logic of the accelerator server has been enhanced to reduce
    the duration of internal locks set/held during load processing.
    Thereby the likeliness of lock concurrencies during parallel
    load processing of accelerator-shadow tables has been reduced
    significantly. As a consequence the likeliness of an occurrence
    of message AQT20111E during load processing has been reduced
    aa well.
    The enhancements has been made part of accelerator
    maintenance level 7.5.5. Upgrade your Accelerator accordingly.
    
    Note:
    For other reasons the error message AQT20111E still may occur
    when using Stored Procedures of the Accelerator.
    For such a situation the recommendation from the APAR's
    local fix-section still applies; it enlarges the period for
    resolution of internal lock conflicts:
    "Add parameter "AQT_DRDA_TIMEOUT=300000" (300.000 milliseconds =
     300 seconds = 5 minutes) to member AQTENV and REFRESH your WLM
     SP address space."
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH29956

  • Reported component name

    ANYTCS ACCLTR Z

  • Reported component ID

    5697DA700

  • Reported release

    750

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-09-28

  • Closed date

    2022-11-18

  • Last modified date

    2022-11-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"750"}]

Document Information

Modified date: