A fix is available
APAR status
Closed as program error.
Error description
When the SYSUT1 template is generated for the Reorg Index utility, an invalid value can be generated for the UNCNT parm - which specifies the # of devices that are to be allocated. Acceptable values for UNCNT must be in the range from 0 to 59. However, this value is currently being set according to the Max Tape Vols/DASD Units field on panel HAA$UREX (Reorg Index Utility options) - which allows values from 0 to 255. As a result, utility execution will fail due to the invalid value. The resolution for this bug will include a new UNCNT field added to panel HAA$DSD (Update dataset options) = which will accept the appropriate values (0 - 59).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Users * **************************************************************** * PROBLEM DESCRIPTION: REORG INDEX utility: Invalid value * * possible for UNCNT keyword when SYSUT1 * * Template is specified. * **************************************************************** * RECOMMENDATION: APPLY the PTF * **************************************************************** .
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PH29483
Reported component name
DB2 AUTOMATION
Reported component ID
5697G6300
Reported release
430
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-09-15
Closed date
2020-11-03
Last modified date
2020-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
HAA$BDSN HAA$BUT2 HAA$BUTI HAA$UC2I HAA$UIMG HAA$UMCI HAA$UOPT HAAARYJ HAABTMP HAACHKJ HAACOPYJ HAADDLX HAADDLY HAADST HAAMODFJ HAAREOIJ HAAREORJ HAAREPRJ HAAREREC HAARUNSJ HAAUREPJ HAAWKDSN
Fix information
Fixed component name
DB2 AUTOMATION
Fixed component ID
5697G6300
Applicable component levels
R430 PSY UI72375
UP20/11/06 P F011
Fix is available