Error description

  • When starting a subscription for refresh or mirror, an
    exception would occur during initializing communication channel
    for above task and is not well handled, this will cause the
    communication channel initialization to fail as well as the
    corresponding task to terminate, and finally the subscription
    starting fails.
    

Local fix

  • Restart the issued subscription.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of InfoSphere CDC for z/OS             *
    ****************************************************************
    * PROBLEM DESCRIPTION: When starting a subscription for mirror *
    *                      or refresh, an exception could occur    *
    *                      during initializing the communication   *
    *                      data channel for any replication task.  *
    *                      This will cause message CHC0330E to be  *
    *                      issued and the corresponding task to be *
    *                      terminated. Finally the subscription    *
    *                      starting fails.                         *
    ****************************************************************
    * RECOMMENDATION: APPLY CORRECTIVE SERVICE                     *
    ****************************************************************
    Subscription starting fails with message CHC0330E.
    

Problem conclusion

  • Add the logic to handle the communication channel initialization
    exception.
    

Temporary fix

  • Restart the failed subscription.
    

Comments

APAR Information

  • APAR number

    PH29025

  • Reported component name

    INFO SRVR CDC Z

  • Reported component ID

    5655U7600

  • Reported release

    A21

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-09-01

  • Closed date

    2020-09-21

  • Last modified date

    2020-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI71659

Modules/Macros

  •    CHCMKINT
    

Fix information

  • Fixed component name

    INFO SRVR CDC Z

  • Fixed component ID

    5655U7600

Applicable component levels

  • RA21 PSY UI71659

       UP20/09/23 P F009

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1"}]

Document Information

Modified date:
05 October 2020