A fix is available
APAR status
Closed as program error.
Error description
ABEND05B, Loop in CQCMSCLS +2C6
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IBM Db2 Query Monitor for z/OS v3.3.0 * * users of component: * * - CQM Data Collector * **************************************************************** * PROBLEM DESCRIPTION: Loop in CQCMSCLS+X'2C6' * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** Loop in CQCMSCLS+X'2C6' when Query Monitor or IBM Security Guardium S-TAP for Db2 is monitoring a large volume of distributed threads.
Problem conclusion
Corrected serialization logic to remove window that caused intermittent storage block chaining errors. Search Keywords: LOOP CQCMSCLS 2C6 ABEND 05B DISTRIBUTED THREADS
Temporary fix
Comments
APAR Information
APAR number
PH28956
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
330
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-09-01
Closed date
2020-10-06
Last modified date
2020-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI71942
Modules/Macros
CQM#PARM CQM#SDIR CQMMINDX CQMMVRFX
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
R330 PSY UI71942
UP20/10/09 P F010
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"3.3.0"}]
Document Information
Modified date: