IBM Support

PH28922: DB SENSOR PROCESS IN IMS HP IMAGE COPY ISSUES BBE1411E AND ITS PROCESS FAILED AFTER PHIDAM DB REORGANIZAED BY OLR

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IMS HP Image Copy passes incorrect information to DB Sensor then
    DB Sensor process failed with BBE1411E.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 2 users ( FMID=H1J0420 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: When active data sets of High           *
    *                      Availability Large Database (HALDB)     *
    *                      are A through J after HALDB online      *
    *                      reorganization (OLR) is done, DB        *
    *                      Sensor under IMS HP Image Copy refers   *
    *                      inactive data sets that are M through   *
    *                      V and DB sensor process fails with      *
    *                      message BBE1411E ( MSGBEP1411E ).       *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    When active data sets of HALDB are A through J after HALDB
    OLR is done, DB Sensor under IMS HP Image Copy refers inactive
    data sets that are M through V and DB sensor process fails with
    message BBE1411E ( MSGBEP1411E ).
    
    If entries of HALDB M through V data set exist in DBRC RECON
    and available data sets are A through J, IMS HP Image Copy
    pulls M through V data sets information from RECON even if they
    not active. Then IMS HP Image Copy calls DB Sensor by using
    inactive data sets. As the result, DB Sensor process tries to
    check the catalog information of inactive data sets that has
    been already deleted by OLR process. Then DB Sensor issues
    the error message and Sensor records are not registered.
    

Problem conclusion

  • IMS HP Image Copy always pulls the active data sets information
    of HALDB from RECON and calls DB Sensor with them.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH28922

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-09-01

  • Closed date

    2020-09-14

  • Last modified date

    2020-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI71517

Modules/Macros

  • FABJDMP2 FABJDMP3 FABJDMP4 FABJDMP5 FABJDMP9 FABJDMPA FABJDMPB
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R420 PSY UI71517

       UP20/09/17 P F009 ¢