A fix is available
APAR status
Closed as program error.
Error description
IMS HP Image Copy passes incorrect information to DB Sensor then DB Sensor process failed with BBE1411E.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 4 Release 2 users ( FMID=H1J0420 ) * **************************************************************** * PROBLEM DESCRIPTION: When active data sets of High * * Availability Large Database (HALDB) * * are A through J after HALDB online * * reorganization (OLR) is done, DB * * Sensor under IMS HP Image Copy refers * * inactive data sets that are M through * * V and DB sensor process fails with * * message BBE1411E ( MSGBEP1411E ). * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When active data sets of HALDB are A through J after HALDB OLR is done, DB Sensor under IMS HP Image Copy refers inactive data sets that are M through V and DB sensor process fails with message BBE1411E ( MSGBEP1411E ). If entries of HALDB M through V data set exist in DBRC RECON and available data sets are A through J, IMS HP Image Copy pulls M through V data sets information from RECON even if they not active. Then IMS HP Image Copy calls DB Sensor by using inactive data sets. As the result, DB Sensor process tries to check the catalog information of inactive data sets that has been already deleted by OLR process. Then DB Sensor issues the error message and Sensor records are not registered.
Problem conclusion
IMS HP Image Copy always pulls the active data sets information of HALDB from RECON and calls DB Sensor with them.
Temporary fix
Comments
APAR Information
APAR number
PH28922
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-09-01
Closed date
2020-09-14
Last modified date
2020-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI71517
Modules/Macros
FABJDMP2 FABJDMP3 FABJDMP4 FABJDMP5 FABJDMP9 FABJDMPA FABJDMPB
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R420 PSY UI71517
UP20/09/17 P F009 ¢
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89E","label":"IMS HP Image Copy"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0"}]