A fix is available
APAR status
Closed as program error.
Error description
Incorrect MSGFABP2053E or ABEND0C4 when running HDPC for image copies of a PHIDAM database that is composed of more than 255 DBDSs including PHIDAM primary indexes.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IBM IMS High Performance Pointer Checker for * * z/OS Version 3 Release 1 (FMID=HPC2310) * * users who run HD Pointer Checker (HDPC) for * * HALDBs. * **************************************************************** * PROBLEM DESCRIPTION: This APAR fixes various problems * * when running HDPC for a HALDB with * * more than 255 DBDSs. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR fixes various problems when running HDPC for a HALDB that is composed of more than 255 DBDSs: - MSGFABP2053E is issued incorrectly when running HDPC with TYPE=ALL on the PROC statement for image copies of a PHIDAM that is composed of more than 255 DBDSs including PHIDAM primary indexes. - ABEND0C4 in the FABPMAIN or FABPSCTL module when running HDPC with TYPE=SCAN on the PROC statement for image copies of a PHIDAM that is composed of more than 255 DBDSs including PHIDAM primary indexes. - MSGFABP2050E is not issued under the following conditions even though HDPC should issue it: - TYPE=ALL is specified on the PROC statement. - Multiple DATABASE statements for one HALDB are specified. - The BLOCKDUMP= parameter are specified on a part of the DATABASE statements. - The following HDPC reports are not printed. Regarding the separator pages for HD Pointer Checker reports, they are not printed even if SEP=YES on the PROC statement is specified. - Separator page for statistics report - Separator page for validation report - Legend for Scan and Validation report - MSGFABP3661E is issued incorrectly when IXKEYCHK=YES is specified.
Problem conclusion
HPPC has been modified to fix the errors.
Temporary fix
Comments
APAR Information
APAR number
PH28701
Reported component name
IMS POINTER CHE
Reported component ID
5655E0900
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-08-24
Closed date
2020-09-14
Last modified date
2020-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI71516
Modules/Macros
FABKCOLL FABPADBS FABPANAL FABPARCK FABPBCTL FABPDBS0 FABPECTL FABPESTM FABPGET1 FABPHCTL FABPHEVS FABPHEXM FABPHEXS FABPHINI FABPHRCK FABPHTRM FABPLBLD FABPLBLX FABPMAIN FABPOUT1 FABPSCTL FABPSTE0 FABPSUMM FABPUCMP FABPUDCT FABPUHDR FABPUHTC FABPUPHR FABPUSPM
Fix information
Fixed component name
IMS POINTER CHE
Fixed component ID
5655E0900
Applicable component levels
R310 PSY UI71516
UP20/09/15 P F009
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89G","label":"IMS HP Pointer Checker"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]
Document Information
Modified date: