Error description

  • EYULPMOD applies USERMOD EYUUM01 to move local MAS modules from
    SEYULOAD to SEYULPA.
    
    But the ++MOVE statements provided in EYU$UM01 member of
    SEYUSAMP still reference modules CJE* that are not provided any
    more in CPSM 5.6.
    
    This produces the following statements in EYULPMOD job:
    
    GIM61901W LMOD CJE9BA01 WAS NOT MOVED BY SYSMOD EYUUM01 BECAUSE
    CJE9BA01 IS NOT IN THE TZONE ZONE.
    GIM61901W LMOD CJE9CM01 WAS NOT MOVED BY SYSMOD EYUUM01 BECAUSE
    CJE9CM01 IS NOT IN THE TZONE ZONE.
    GIM61901W LMOD CJE9MN01 WAS NOT MOVED BY SYSMOD EYUUM01 BECAUSE
    CJE9MN01 IS NOT IN THE TZONE ZONE.
    GIM61901W LMOD CJE9NA01 WAS NOT MOVED BY SYSMOD EYUUM01 BECAUSE
    CJE9NA01 IS NOT IN THE TZONE ZONE.
    GIM61901W LMOD CJE9PS01 WAS NOT MOVED BY SYSMOD EYUUM01 BECAUSE
    CJE9PS01 IS NOT IN THE TZONE ZONE.
    GIM61901W LMOD CJE9TS01 WAS NOT MOVED BY SYSMOD EYUUM01 BECAUSE
    CJE9TS01 IS NOT IN THE TZONE ZONE.
    GIM61901W LMOD CJE9WM01 WAS NOT MOVED BY SYSMOD EYUUM01 BECAUSE
    CJE9WM01 IS NOT IN THE TZONE ZONE.
    GIM61901W LMOD CJE9XC01 WAS NOT MOVED BY SYSMOD EYUUM01 BECAUSE
    CJE9XC01 IS NOT IN THE TZONE ZONE.
    GIM61901W LMOD CJE9XD01 WAS NOT MOVED BY SYSMOD EYUUM01 BECAUSE
    CJE9XD01 IS NOT IN THE TZONE ZONE.
    GIM61901W LMOD CJE9XL01 WAS NOT MOVED BY SYSMOD EYUUM01 BECAUSE
    CJE9XL01 IS NOT IN THE TZONE ZONE.
    GIM61901W LMOD CJE9XM01 WAS NOT MOVED BY SYSMOD EYUUM01 BECAUSE
    CJE9XM01 IS NOT IN THE TZONE ZONE.
    GIM61901W LMOD CJE9XQ01 WAS NOT MOVED BY SYSMOD EYUUM01 BECAUSE
    CJE9XQ01 IS NOT IN THE TZONE ZONE.
    GIM61901W LMOD CJE9XS01 WAS NOT MOVED BY SYSMOD EYUUM01 BECAUSE
    CJE9XS01 IS NOT IN THE TZONE ZONE.
    GIM61901W LMOD CJE9XZ01 WAS NOT MOVED BY SYSMOD EYUUM01 BECAUSE
    CJE9XZ01 IS NOT IN THE TZONE ZONE.
    GIM22701I APPLY PROCESSING WAS SUCCESSFUL FOR SYSMOD EYUUM01.
    GIM20501I APPLY PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE
    WAS 04.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V5R6M0 Users.                *
    ****************************************************************
    * PROBLEM DESCRIPTION: EYU$UM01 attempts to move CJE9xx01      *
    *                      modules to the LPA but these modules    *
    *                      are not built for CICSPlex SM V5.6.     *
    ****************************************************************
    EYU$UM01 is a pre-supplied SMP/E USERMOD which can be used
    to move LPA eligible modules into the SEYULPA library.
    The EYU$UM01 USERMOD contains references to modules not shipped
    with CPSM V5.6.
    These cause message GIM61901W to be issued by SMPE, accompanied
    by return code 4.
    
    
    In a secondary issue, data set member EYU$M720 was omitted
    from the SEYUSAMP library.
    
    Additional Keywords: msgGIM61901W RC4 EYUUM01
    CJE9BA01 CJE9CM01 CJE9MN01 CJE9NA01 CJE9PS01 CJE9TS01 CJE9WM01
    CJE9XC01 CJE9XD01 CJE9XL01 CJE9XM01 CJE9XQ01 CJE9XS01 CJE9XZ01
    

Problem conclusion

  • EYU$UM01 has been corrected so that the ++MOVE statements for
    CJE9xx01 modules have been removed.
    To achieve this the content of the usermod has been shifted
    right one character. Users wishing to apply usermod EYUUM01
    must first edit EYU$UM01 and move the content back one place
    to the left.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH28624

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    30M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / CST / Xsystem

  • Submitted date

    2020-08-19

  • Closed date

    2020-09-22

  • Last modified date

    2020-10-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    010PC2Ÿ UI71683

Modules/Macros

  • EYU$M720 EYU$UM01
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R30M PSY UI71683

       UP20/09/25 P F009

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.6"}]

Document Information

Modified date:
10 October 2020