IBM Support

PH28520: ABEND (CODE 0C7/AKEA) OCCURRS IN PROGRAM CCVSWASH.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Abend is in module CCVSWASH.
    
    The psw is pointing to a ZAP
    instruction. The 0C7 abend appears to be
    occurring because the
    second value is initialized to blanks and does
    not contain a
    valid 4-byte Packed Number.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of CICS Configuration Manager.     *
    ****************************************************************
    * PROBLEM DESCRIPTION: Abend0C7 / abendAKEA occurs in program  *
    *                      CCVSWASH.                               *
    ****************************************************************
    An abendS0C7 occurs in module CCVSWASH.
    
    The PSW is pointing to a ZAP instruction. The S0C7 abend occurs
    because the second value is initialized to blanks and does
    not contain a valid 4-byte Packed Number.
    

Problem conclusion

  • CICS Configuration Manager is corrected.
      1. An uninitialized storage condition is now corrected.
    
      2. The cleanup code in CCVSWASH will now validate the TS QNAME
         to ensure only the correct elements are processed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH28520

  • Reported component name

    CICS CONFIG MGR

  • Reported component ID

    5697CIC00

  • Reported release

    540

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-08-14

  • Closed date

    2020-09-23

  • Last modified date

    2020-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI71727

Modules/Macros

  • CCVSMSGH CCVSWASH
    

Fix information

  • Fixed component name

    CICS CONFIG MGR

  • Fixed component ID

    5697CIC00

Applicable component levels

  • R540 PSY UI71727

       UP20/09/25 P F009

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2L7A","label":"CICS Configuration Manager for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4"}]

Document Information

Modified date:
05 October 2020