Error description
Abend is in module CCVSWASH. The psw is pointing to a ZAP instruction. The 0C7 abend appears to be occurring because the second value is initialized to blanks and does not contain a valid 4-byte Packed Number.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of CICS Configuration Manager. * **************************************************************** * PROBLEM DESCRIPTION: Abend0C7 / abendAKEA occurs in program * * CCVSWASH. * **************************************************************** An abendS0C7 occurs in module CCVSWASH. The PSW is pointing to a ZAP instruction. The S0C7 abend occurs because the second value is initialized to blanks and does not contain a valid 4-byte Packed Number.
Problem conclusion
CICS Configuration Manager is corrected. 1. An uninitialized storage condition is now corrected. 2. The cleanup code in CCVSWASH will now validate the TS QNAME to ensure only the correct elements are processed.
Temporary fix
Comments
APAR Information
APAR number
PH28520
Reported component name
CICS CONFIG MGR
Reported component ID
5697CIC00
Reported release
540
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-08-14
Closed date
2020-09-23
Last modified date
2020-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI71727
Modules/Macros
CCVSMSGH CCVSWASH
Fix information
Fixed component name
CICS CONFIG MGR
Fixed component ID
5697CIC00
Applicable component levels
R540 PSY UI71727
UP20/09/25 P F009
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2L7A","label":"CICS Configuration Manager for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4"}]
Document Information
Modified date:
05 October 2020