Error description

  • If DB2 is brought down forcefully or fails, and is then
    restarted, some URs that were not yet completed may be marked
    "in doubt".  If such a UR is subsequently processed with the DB2
     -RECOVER INDOUBT command, and is ROLLedBACK, it is possible
    that a UR Control record sequencing error will be raised by IIDR
     CDC for z/OS, issuing message CHC1528E and ending the
    subscription.
    

Local fix

  • No local fix is available
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IIDR CDC for z/OS.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: In-doubt URs should be resolved for     *
    *                      replication based on how they were      *
    *                      resolved in the DB2 Log.  No external   *
    *                      configurable setting should be used.    *
    ****************************************************************
    * RECOMMENDATION: APPLY CORRECTIVE SERVICE                     *
    ****************************************************************
    
    The current approach to resolving in-doubt URs is insufficient
    and can lead to desynchronization of source and target tables.
    

Problem conclusion

  • In-doubt URs will be held in the Staging Space until a logged
    resolution (COMMIT or ABORT) is encountered and used to dispose
    of the UR.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH27203

  • Reported component name

    INFO SRVR CDC Z

  • Reported component ID

    5655U7600

  • Reported release

    A21

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-07-08

  • Closed date

    2020-10-29

  • Last modified date

    2020-11-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI72338

Modules/Macros

  •    CHCDLSGP CHCDSCPF CHCMBARA CHCMBCHS CHCMBCHT
    CHCMBDAN CHCMBDES CHCMBDEU CHCMBELL CHCMBENG CHCMBENP CHCMBENU
    CHCMBESP CHCMBFIN CHCMBFRA CHCMBFRB CHCMBFRC CHCMBFRS CHCMBHEB
    CHCMBISL CHCMBITA CHCMBITS CHCMBJPN CHCMBKOR CHCMBNLB CHCMBNLD
    CHCMBNOR CHCMBPTB CHCMBPTG CHCMBRMS CHCMBRUS CHCMBSVE CHCMBTHA
    CHCMBTRK CHCMBZZZ CHCPAAUT CHCSTGSP
    

Publications Referenced
SC19412700    

Fix information

  • Fixed component name

    INFO SRVR CDC Z

  • Fixed component ID

    5655U7600

Applicable component levels

  • RA21 PSY UI72338

       UP20/10/31 P F010 Ø

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1"}]

Document Information

Modified date:
03 November 2020