A fix is available
APAR status
Closed as program error.
Error description
When CICS is initializing there is a call to see if IBM® z/OS® Workload Interaction Correlator which produces DFHMN0001 ABNED0C4 in DFGMNSU. CICS is starting up, and the domains are initializing. Monitor Domain starts initialization and starts various activities. . PA and XM domains drive DFHMNSU which calls DFHMNSVC to issue PB_CREATE. Meanwhile, at some point, MN domain wants to find out if ZWIC is needed and drives DFHMNSU which calls DFHMNSVC to issue ZWIC_REGISTER. If the DFHMNSU->DFHMNSVC->ZWIC_REGISTER call happens while all of those DFHMNSU->DFHMNSVC->PB_CREATE are occurring, then there can be a conflict in the use of the MAFPB control block.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users. * **************************************************************** * PROBLEM DESCRIPTION: CICS initialisation abends when the * * Monitoring Domain tries to initialise * * a zWIC (IFAWIC) buffer using a null * * pointer. * **************************************************************** CICS initialisation fails with an 0C4 abend in module DFHMNSU on an EXECUTE instruction: 4490 6008. The error can be reported at offset X'1620' or X'1A8C' in DFHMNSU. The EX target instruction is an XC: D700 7000 7000. The problem is that Register 7 is 00000000_00000000 causing the XC instruction to fail. MN domain has called DFHMNSVC to obtain a zWIC buffer, but the call failed, and returned a null pointer. Subsequent use of the null pointer caused the 0C4. Keywords: mna_state_lock
Problem conclusion
DFHMNSU has been changed to serialise calls to DFHMNSVC for zWIC buffer allocation.
Temporary fix
Comments
APAR Information
APAR number
PH26672
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
300
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / CST / Xsystem
Submitted date
2020-06-22
Closed date
2020-06-23
Last modified date
2021-01-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI70186
Modules/Macros
DFHMNDM
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R300 PSY UI70186
UP20/06/27 P F006
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.6"}]
Document Information
Modified date: