Error description

  • Db2 Administration Tool:
    
    The sequence of two dependent rename column statements,
    referring to the same table, is switched during generation of
    the WSL.  The execution of the change then fails with a -601
    SQLCODE due to the wrong sequence of the statements. The
    statements are originally provided in a way that would allow
    execution of the dependent rename first.
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of the DB2 Object Comparison Tool for  *
    *                 Z/OS who save their compare results.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: When user specifies change statements   *
    *                      for renaming dependent columns          *
    *                      correctly, Admin Tool switches the      *
    *                      statements to be processed in order of  *
    *                      columns in the table. Thereby not       *
    *                      renaming dependent columns first.       *
    *                                                              *
    *                      For example, the two alters are added   *
    *                      in this order:                          *
    *                                                              *
    *                      ALTER TABLE T1                          *
    *                      RENAME COLUMN C1 to C1_NEW;             *
    *                      ALTER TABLE T1                          *
    *                      RENAME COLUMN C1_OLD TO C1;             *
    *                      The order of the alters ends up         *
    *                      switched, so when                       *
    *                      ALTER TABLE T1                          *
    *                      RENAME COLUMN C1_OLD TO C1;             *
    *                      is run first, it fails with an          *
    *                      sqlcode -601 as column C1               *
    *                      still exists.                           *
    ****************************************************************
    Admin Tool processes rename statements in the incorrect order
    when analyzing rename statements provided in the correct order.
    

Problem conclusion

  • The issue has been resolved.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH26292

  • Reported component name

    DB2 ADMIN TOOL

  • Reported component ID

    568851500

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-06-11

  • Closed date

    2020-09-08

  • Last modified date

    2020-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI71454

Modules/Macros

  • ADB2CMT
    

Fix information

  • Fixed component name

    DB2 ADMIN TOOL

  • Fixed component ID

    568851500

Applicable component levels

  • RC10 PSY UI71454

       UP20/10/01 P F009

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSCVQTD","label":"IBM Db2 Administration Tool for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"12.1.0"}]

Document Information

Modified date:
12 February 2021