Error description

  • Miscellaneous Bug Fixes FA 14.1.12
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Fault Analyzer Version 14 users.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: 01. Message IDI0131W ENQ on $$INDEX     *
    *                          held by IDIS of another LPAR.       *
    *                          APAR PH30098                        *
    *                      02. IDI0005 in CICS transaction         *
    *                          analysis.                           *
    *                          APAR PH26215                        *
    *                      03. XCF shutdown causes subsystem to    *
    *                          stop.                               *
    *                          APAR PH26267                        *
    *                      04. Abend0C4 in IDIXDCAP when Fault     *
    *                          Analyzer is not enabled in IFAPRDxx *
    *                          APAR PH26407                        *
    *                      05. ABEND0C4 in IDIXCMxx modules.       *
    *                          Register 15 shows a 64-bit value    *
    *                          in AMODE64 code.                    *
    *                          APAR PH27076                        *
    *                      06. IDI0184W Unable to allocate         *
    *                          extended dump data set : XDUMPDSN   *
    *                          not specified or NULLFILE           *
    *                          high-level qualifier                *
    *                          APAR PH28812                        *
    *                      07. ABEND0C4 in IDICCFND or other CICS  *
    *                          application issue like ABEND0C6.    *
    *                          APAR PH29199                        *
    *                      08. FA Plugin does not behave correctly *
    *                          when the workspace is corrupt.      *
    *                          The UI enters a loop and needs to   *
    *                          be manually stopped by the user     *
    *                          APAR PH27309                        *
    *                      09. In the Fault Analyzer Eclipse GUI a *
    *                          message "Source not found" appears  *
    *                          when clicking on a line number      *
    *                          link.                               *
    *                          APAR PH30097                        *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF                       *
    ****************************************************************
    01. Problem with deletion of migrated dump data sets associated
        with auto-managed fault entry deletion.
    02. Repeated references to a large CICS container was eventually
        causing the IDI0005 due to insuffient 31-bit storage
    03. A fatal error ECB check loop also checked the XCF ECB
        unconditionally.
    04. Linkage stack is not unstacked in the correct sequence.
    05. Register 15 has a value in the high-order word.
    06. XDUMP pages are accumulated during real time analysis even
        though XDUMP data set could not be allocated.
    07. FAST duplicate processing is setting a pointer to zero.
        A four byte MVC will either generate an ABEND0C4 or an
        application issue.
    08. When the workspace is corrupt the 'default history' loaded
        file can not be created, so the fa plugin attempted to load
        the default history file infinitely.
    09. The Host code is not always sending the associated listing
        files to the Fault Analyzer Eclipse GUI when a fault entry
        is opened.
    

Problem conclusion

  • 01. Deletion of migrated tightly-coupled associated dump data
        sets is now performed via BPX batch job to prevent the ENQ
        from affecting Fault Analyzer operation.
    02. The incorrect repeated container reference was fixed.
    03. Code has been modified to trigger XCF cleanup but then to
        continue processing as documented.
    04. Linkage stack is unstacked correctly.
    05. Load instruction is changed to load 31 bits correctly.
    06. XDUMP pages are only accumulated if an XDUMP data set is
        allocated.
    07. The pointer is correctly set in IDICCFND processing.
    08. When we detect there is workspace corruption, we repair the
        workspace corruption, then are able to load the default
        history file correctly.
    09. The host code has been corrected to always send the listing
        files when a fault entry is opened.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH26070

  • Reported component name

    FAULT ANALYZER

  • Reported component ID

    5655Q4100

  • Reported release

    E10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-06-04

  • Closed date

    2020-10-12

  • Last modified date

    2020-11-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI71892

Modules/Macros

  • IDI64MF  IDI64MSG IDI64SPC IDI64UTL IDIACCEP IDIALSMP IDIAPPLY
    IDIBIND  IDICAASM IDICABND IDICADY6 IDICADYN IDICAFA6 IDICAFAT
    IDICALE  IDICALE6 IDICALO6 IDICALOC IDICASB6 IDICASM6 IDICASUB
    IDICBDB2 IDICBFAT IDICBIMS IDICCFND IDICGPR1 IDICGPR2 IDICHKI
    IDICISA  IDICNF00 IDICNFDS IDICNOT6 IDICNOTA IDICNOTR IDICONFM
    IDICOPY  IDICOPY6 IDICOPYR IDICRXDX IDICRXEI IDICRXET IDICRXHC
    IDICRXLE IDICSDB2 IDICSIMS IDICSMF  IDICSPC  IDICSRB  IDICSSRB
    IDICSV05 IDICSV06 IDICSV08 IDICSV09 IDICSV10 IDICSV11 IDICSV12
    IDICSV13 IDICSV14 IDICSV15 IDICSVCR IDICSXDS IDICUXCS IDICUXWR
    IDICXITA IDICZSVC IDIDA    IDIDASUB IDIDATSA IDIDATST IDIEAI
    IDIEAI0  IDIECASB IDIGMAIN IDIGNTCE IDIGSVRJ IDIGUOPT IDIGWEBB
    IDIHEACK IDIHIBMA IDIHIBMI IDIHIBMM IDIHPMSG IDIHUSRM IDIJAGNQ
    IDIJAGNT IDILEDS  IDIM00   IDIM01   IDIM02   IDIM03   IDIM04
    IDIM05   IDIM06   IDIM07   IDIM08   IDIM09   IDIM10   IDIMCICS
    IDINDEX  IDINDFUE IDIOPTLM IDIPABOT IDIPADIR IDIPANEX IDIPASID
    IDIPASUB IDIPBLNK IDIPBOPT IDIPCE   IDIPCONF IDIPCOPY IDIPCSTG
    IDIPCTNM IDIPCTRF IDIPDA   IDIPDDIR IDIPDIRL IDIPDISP IDIPDOPT
    IDIPDSCA IDIPDSCP IDIPDSCU IDIPEM01 IDIPFMIP IDIPH000 IDIPH001
    IDIPH002 IDIPH003 IDIPH004 IDIPH005 IDIPH006 IDIPH007 IDIPH008
    IDIPH100 IDIPH101 IDIPH102 IDIPH103 IDIPH104 IDIPH105 IDIPH106
    IDIPH107 IDIPH108 IDIPH109 IDIPH110 IDIPH111 IDIPH112 IDIPH113
    IDIPH114 IDIPH115 IDIPH116 IDIPH117 IDIPH118 IDIPH119 IDIPH120
    IDIPH121 IDIPH122 IDIPH123 IDIPH124 IDIPH125 IDIPH126 IDIPH127
    IDIPH128 IDIPH129 IDIPH130 IDIPH131 IDIPH132 IDIPH133 IDIPH134
    IDIPH135 IDIPH136 IDIPH137 IDIPH138 IDIPH139 IDIPH140 IDIPH141
    IDIPH142 IDIPH143 IDIPH144 IDIPH145 IDIPH146 IDIPH147 IDIPH148
    IDIPH149 IDIPH150 IDIPH151 IDIPH152 IDIPH153 IDIPH154 IDIPH155
    IDIPH156 IDIPH157 IDIPH158 IDIPH159 IDIPH160 IDIPH161 IDIPH162
    IDIPH163 IDIPH164 IDIPH165 IDIPH166 IDIPH167 IDIPH168 IDIPH169
    IDIPH170 IDIPH171 IDIPH172 IDIPH173 IDIPH174 IDIPH175 IDIPH176
    IDIPH177 IDIPH178 IDIPH179 IDIPH180 IDIPH181 IDIPH182 IDIPH183
    IDIPH184 IDIPH185 IDIPH186 IDIPH187 IDIPH188 IDIPH189 IDIPH190
    IDIPH191 IDIPH192 IDIPH193 IDIPH194 IDIPH195 IDIPH196 IDIPH197
    IDIPH198 IDIPH199 IDIPH200 IDIPH201 IDIPH202 IDIPH203 IDIPH204
    IDIPH205 IDIPH206 IDIPH207 IDIPH208 IDIPH209 IDIPH210 IDIPH211
    

Fix information

  • Fixed component name

    FAULT ANALYZER

  • Fixed component ID

    5655Q4100

Applicable component levels

  • RE10 PSY UI71892

       UP20/11/02 P F010

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"E10"}]

Document Information

Modified date:
03 November 2020