Error description
When many IMS Type-2 commands are issued, IMS Operation Manager address space with Sysplex Manager can cause ABENDS878-0C.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Sysplex manager. * **************************************************************** * PROBLEM DESCRIPTION: IMS Operation Manager address space * * with Sysplex Manager can cause * * ABENDS878-0C. * **************************************************************** * RECOMMENDATION: Apply the PTF that corrects this APAR. * **************************************************************** The user exits for OM audit trail provided by Sysplex Manager obtain several buffers when an IMS type-2 command is issued. Since the user exits release the buffer with improper length, 8K-byte length storage remains as a garbage per one IMS type-2 command. Therefore, ABENDS878-0C occurs when many IMS type-2 commands are issued.
Problem conclusion
The user exits for OM audit trial have been changed to release the buffer with proper length.
Temporary fix
Comments
APAR Information
APAR number
PH25526
Reported component name
IMS SYSPLEX MGR
Reported component ID
5655P0100
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-05-18
Closed date
2020-05-29
Last modified date
2020-07-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI69762
Modules/Macros
GJEOCXC0
Fix information
Fixed component name
IMS SYSPLEX MGR
Fixed component ID
5655P0100