  • DFHMQ0125 E date time applid Cannot retrieve data from a START
    command. EIBFN=X'CE24' EIBRESP=16 EIBRESP2=2
    
    is issued because there is a contention problem where one CKTI
    task has been delayed by a lot of CLS2 synchronization activity
    taking place.
    
    This first CKTI task was started by the CKAM transaction and has
    been delayed for some seconds due to the CLS2 activity. When the
    WLMHEALTH percentage was next incremented, transaction CKAM was
    posted again and because this CKTI had not yet been able to set
    the MQMONITOR started, CKAM issued another EXEC CICS START
    command to set the MQMONITOR started, creating a second CKTI
    instance.
    
    The second CKTI was not delayed by the CLS2 activity, which was
    still ongoing, and set DFHMQMINI to started. When the first CKTI
    task resumed, DFHMQINI was already started and the EXEC CICS SET
    MQMONITOR STARTED command failed.
    
    This APAR intends to fix the above problem and will also change
    the description of the message DFHMQ0125.
    
    Currently the text of the message DFHMQ0125 is:
    
    DFHMQ0125 E date time applid Cannot retrieve data from a START
    command. EIBFN=X'eibfn' EIBRESP=eibresp EIBRESP2=eibresp2.
    
    It will be changed to read:
    
    DFHMQ0125 E date time applid Unable to set mqmonitor
    <name> started. EIBFN=X'eibfn' EIBRESP=eibresp
    EIBRESP2=eibresp2.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: The message text for DFHMQ0125 is       *
    *                      incorrect.                              *
    ****************************************************************
    Message text for DFHMQ0125 is incorrect. This message is
    produced when two CKTI transactions are running simultaneously
    and one issues an EXEC CICS SET MQMONITOR immediately after the
    first transaction has done so. This can happen when WLMHEALTH is
    active and the transactions have been delayed by other factors
    in the region.
    Keywords: DFHMQ0125 MQ0125
    

Problem conclusion

  • The message DFHMQ0125 has been changed to read "Unable
    to set mqmonitor <name> started." and code has been added to
    cater for two CKTI or CKBR tasks simultaneously attempting to
    set the same MQMONITOR resource started.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH25261

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-05-11

  • Closed date

    2020-06-18

  • Last modified date

    2020-07-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI70132 UI70133 UI70135 UI70136

Modules/Macros

  • DFHMEMQC DFHMEMQE DFHMEMQK DFHMQBID DFHMQCM@ DFHMQP0@ DFHMQP1@
    DFHMQP3@ DFHMQR0@ DFHMQTSK
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R100 PSY UI70132

       UP20/06/19 P F006

  • R103 PSY UI70133

       UP20/06/19 P F006

  • R200 PSY UI70135

       UP20/06/19 P F006

  • R300 PSY UI70136

       UP20/06/29 P F006