IBM Support

PH25036: EYUVC1231 ERROR TRYING TO ADD A TX AFTER DISCARD IT FROM CPSM "ACTIVE WORKLOAD DYNAMIC TRANSACTION"

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • EYUVC1231 error message is issued trying to modify a workload.
    The problem occurs after the workload has previously been
    modified by a request sent to a different CMAS.
    For example, the problem might occur when installing a new
    Workload definition, or when removing a transaction using the
    "Active workload dynamic transaction" view of the CICSplex SM
    Web User Interface (WUI) or equivalent view in CICS Explorer.
    
    The CMAS handling the failing request will emit an exception
    trace entry from module WSCL with debug text ELECTFRA.
    
    EYUVC1231E  'Force' (FORCE) request failed.
                Request complete for 1 records. (Failed, Exception)
    .
    CNX0593E: RESPONSE(FAILED) REASON(EXCEPTION)
    

Local fix

  • No Local Fix.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM users.                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: EYUVC1231 error message is issued when  *
    *                      trying to modify a workload.            *
    ****************************************************************
    The problem occurred when two CMASes, CMASA and CMASB, were used
    to manage a workload. CMASB was terminated and restarted using a
    WARM start but a timing issue caused CMASA to remain unaware
    that CMASB was again involved with the workload.
    A request to change the workload was sent to CMASA. This
    completed successfully but CMASA had not contacted
    CMASB when obtaining the necessary locks. When a subsequent
    request to change the workload was sent to CMASB error message
    EYUVC1231 was issued because the internal locking state was
    inconsistent.
    

Problem conclusion

  • CICSPlex SM has been changed to resolve the timing issue on the
    WARM start of a CMAS that is involved in managing workloads.
    Notification of the CMAS's return is broadcast to other CMASes
    also involved in managing those workloads.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH25036

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-05-05

  • Closed date

    2020-08-04

  • Last modified date

    2020-09-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI70887 UI70888 UI70889

Modules/Macros

  • EYU0CPAE EYU0WMWS EYU0WSCL EYU0WSRL EYU9CMP3 EYU9CMP4 EYU9CMPU
    EYU9CMR3 EYU9CMR4 EYU9CMRU
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R10M PSY UI70889

       UP20/08/06 P F008

  • R20M PSY UI70888

       UP20/08/06 P F008

  • R30M PSY UI70887

       UP20/08/06 P F008

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: