IBM Support

PH24779: ENHANCEMENT TO THE LICON UTILITY OF INTEGRITY CHECKER TO SUPPORT IMS DIRECTORY

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • This APAR enables the LICON utility of Integrity Checker to
    create RDE to the LICON data set from IMS directory or validate
    RDEs in the LICON data set with ACBs in IMS directory.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    
    * USERS AFFECTED: IMS Library Integrity Utilities for z/OS,    *
    
    *                 Version 2 Release 2 (FMID=H27P220) users     *
    
    *                 who use the Integrity Checker utility.       *
    
    ****************************************************************
    
    * PROBLEM DESCRIPTION: This APAR provides the LICON utility of *
    
    *                      the Integrity Checker utility to use    *
    
    *                      IMS directory as input.                 *
    
    ****************************************************************
    
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    
    ****************************************************************
    
    This APAR enhances the LICON utility of the Integrity Checker
    utility to use IMS directory as input.
    
    User can specify IMS directory to create an RDE with INIT.DB
    command. The VERIFY.DB command also supports IMS directory as
    input to verify the ACBs in the IMS directory against the RDEs
    stored in the LICON data set.
    
    
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    The documentation "IBM IMS Library Integrity Utilities for z/OS
    V2R2, User's Guide (SC19-3979-05)" is changed.
    
    For all the documentation changes, see documentation updates
    on IMS Tools library site.
    https://www.ibm.com/support/pages/node/712955#imsliu-lib
    

Problem conclusion

  • IMSMGDACBS/K
    

Temporary fix

Comments

  • The following modules and macros have been modified.
    FABLBA0A, FABLBA0B, FABLBA0C, FABLBA0D, FABLBA0E, FABLBA0F,
    FABLIDBA, FABLIDBB, FABLIDBC, FABLIDBD, FABLIDBE, FABLIDBF,
    FABLIDR0, FABLIRD0, FABLISI0, FABLIU00, FABLRCKA, FABLRCKB,
    FABLRCKC, FABLRCKD, FABLRCKE, FABLRCKF, FABLWMT, FABLASCD,
    FABLBA00, FABLIDB0, FABLRCK0
    

APAR Information

  • APAR number

    PH24779

  • Reported component name

    IMS LIBR INTEG

  • Reported component ID

    5655I4200

  • Reported release

    220

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2020-04-28

  • Closed date

    2020-06-29

  • Last modified date

    2024-12-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI70303

Modules/Macros

  • FABLBA0A FABLBA0B FABLBA0C FABLBA0D FABLBA0E FABLBA0F FABLIDBA
    FABLIDBB FABLIDBC FABLIDBD FABLIDBE FABLIDBF FABLIDR0 FABLIRD0
    FABLISI0 FABLIU00 FABLRCKA FABLRCKB FABLRCKC FABLRCKD FABLRCKE
    FABLRCKF FABLWMT
    

Publications Referenced
SC19397905    

Fix information

  • Fixed component name

    IMS LIBR INTEG

  • Fixed component ID

    5655I4200

Applicable component levels

  • R220 PSY UI70303

       UP20/07/01 P F006  

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]

Document Information

Modified date:
04 December 2024