IBM Support

PH24705: DISPLAY DATABASE COMMAND WITH RESTRICT LIMIT(*) ABENDS0C4 PIC11 IN DSNTDSTG OFFSET00210

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND0C4 RC00000011 RC11 DSNTDSTG+00210 seen for -DISPLAY
    DATABASE command with RESTRICT LIMIT(*) and the below dump
    produced :
    
    DT21,ABND=0C4-00000011,U=SYSOPR ,M=N ,C=121.SCC
    -DBCMND ,M=DSNTFRCV,LOC=DSNTDC .DSNTDSTG+00210
    
    Additional symptoms: ABEND0C4 PIC11 DSNTDMST+03F96 OFFSET03F96
                         CLAIMERS LIMIT(*) DSNTDMST+02286
                         OFFSET02286 -DIS DB(xxxxxxx) SPACE(*)
                         LIMIT(*)
    
                         ABEND0C4 PIC04 DSNTDCST+03188 OFFSET03188
                         ABEND0C4 PIC04 DSNXKBLM+00CA2 OFFSET00CA2
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Db2 V12 for z/OS Administrators that                     *
    * execute DISPLAY DB command.                                  *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Several jobs of DISPLAY DB commands                          *
    * were canceled and abended at different                       *
    * modules: DSNTDMST, DSNTDSTG and                              *
    * DSNTDMUL.                                                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply corrective PTF when available                          *
    ****************************************************************
    There are multiple workloads that are running multiple jobs
    with the DISPLAY DB commands. Some of them were canceled
    and caused the abends at the different place such as:
    -DIS DATABASE( ) SPACE() RESTRICT LIMIT(*)
    DT21,ABND=0C4-00000011,U=SYSOPR ,M=N ,C=121.SCC -DBCMND ,
    M=DSNTFRCV,LOC=DSNTDC .DSNTDSTG+00210
    -DIS DB(DSNDB06 ) SP() CLAIMERS LIMIT(*)
    DT23,ABND=0C4-00000011,U=SYSOPR ,M=N ,C=121.SCC -DBCMND ,
    M=DSNTFRCV,LOC=DSNTDC .DSNTDMST+03F96
    

Problem conclusion

  • The fix is to ensure the buffer pool used
    by DISPLAY DB command is freed only when
    no module is accessing it.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH24705

  • Reported component name

    DB2 OS/390 & Z/

  • Reported component ID

    5740XYR00

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-04-22

  • Closed date

    2020-05-18

  • Last modified date

    2021-05-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI69570

Modules/Macros

  • DSNTDDIS
    

Fix information

  • Fixed component name

    DB2 OS/390 & Z/

  • Fixed component ID

    5740XYR00

Applicable component levels

  • RC10 PSY UI69570

       UP20/05/27 P F005

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"Db2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"12.0"}]

Document Information

Modified date: