Error description

  • When using the IBM ClearCase GUI version tree browser on
    Windows, hovering over a version with an over-long comment or
    other metadata will cause the tooltip to flash on the screen.
    
    One example would be a directory that was checked in after
    adding a large number of files to source control. In that case,
    the default checkin comment would read:
    "Added element 'file1.txt'
     Added element 'file2.txt'
     ...
     Added element 'file100.txt'"
    
    If the number of lines in the comment would cause the tooltip to
    be taller than the screen, the tooltip will rapidly appear and
    disappear.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of the ClearCase native GUI vtree browser.             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Hovering over version in GUI vtree browser with multi-line   *
    * command or other large amount of metadata causes tool-tip to *
    * flicker                                                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • A fix is available in ClearCase versions 9.0.1.11 and 9.0.2.3
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH24275

  • Reported component name

    CLEARCASE WIN

  • Reported component ID

    5724G2900

  • Reported release

    901

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-04-09

  • Closed date

    2020-12-22

  • Last modified date

    2020-12-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CLEARCASE WIN

  • Fixed component ID

    5724G2900

Applicable component levels

  • R901 PSY

       UP

  • R902 PSY

       UP