Error description

  • Formatting dumps with the CICSPlex SM dump formatting routine
    VERBX EYU9Dnnn can print inaccurate timestamp values.
    This occurs when formatting stored clocks values for stack
    creation times, and when formatting the CMAS-MAS connection
    summary.
    The problem arises when the dump being formatted originated
    on a different MVS image from where IPCS is executing.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM users.                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: Formatting a CICSPlex SM dump using     *
    *                      VERBX EYU9Dnnn with either the COM or   *
    *                      TASKS keywords will print some          *
    *                      timestamps in LOCAL time.               *
    *                      Due to an error in the time conversion  *
    *                      process these timestamps are converted  *
    *                      to local time incorrectly.              *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves         *
    *                 PH23886, restart any IPCS sessions pointing  *
    *                 to the version of EYU9D520, EYU9D530,        *
    *                 EYU9D540, or EYU9D550 distributed by the     *
    *                 PTF. A link list update and LLA refresh may  *
    *                 be required where these modules are held     *
    *                 in the linklist.                             *
    ****************************************************************
    Formatting a CICSPlex SM SVC dump using any of
    VERBX EYU9D520
    VERBX EYU9D530
    VERBX EYU9D540
    VERBX EYU9D550
    with either the COM or TASKS keywords will print some stored
    clock values in LOCAL time. The affected timestamps appear
    in the following sections of the formatted dump report:
    - Kernel linkage summary for component <componentID>
    - CMAS-CMAS direct connection summary for <cmasname>
    - CMAS-MAS connection summary for <cmasname>
    
    An error fetching the CVT while converting the timestamps
    means that these timestamps are converted into local
    time incorrectly, therefore the value displayed is not an
    accurate representation of the stored clock value.
    The CVTLSO and CVTLDTO values are required for local time
    conversion.
    This error occurs when the address space running the the
    dump formatting routine executes on a different zOS LPAR
    to where the dump was captured, or during a different IPL
    of the same LPAR.
    

Problem conclusion

  • Modules EYU0DVKF and EYU0DVOF have been updated to interpret
    the STCK values correctly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH23886

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    90M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-03-31

  • Closed date

    2020-04-28

  • Last modified date

    2020-06-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI69214 UI69215 UI69216 UI69217

Modules/Macros

  • EYU0DVKF EYU0DVOF
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R00M PSY UI69216

       UP20/05/01 P F004

  • R10M PSY UI69217

       UP20/05/01 P F004

  • R20M PSY UI69215

       UP20/05/01 P F004

  • R90M PSY UI69214

       UP20/05/02 P F005

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
02 June 2020