A fix is available
APAR status
Closed as program error.
Error description
When using combo mode the way of log processing is detected for each partition/tablespace. If there were several tablespaces with REORG/LOAD LOG NO from the start time to the current time, the log processing mode is incorrectly detected, which can cause ALAA061W plus ALAA440E. Possible incorrect ALAA486E error message: "Versioning data not available for table: DBID,PSID,OBID".
Local fix
Choose Log Forward mode to force product to read the logs forward for all objects.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Db2 Log Analysis Tool for z/OS * **************************************************************** * PROBLEM DESCRIPTION: 1. Incorrect Combo mode processing when * * several tablespaces had REORG/LOAD * * with LOG NO option. * * 2. Possible incorrect ALAA486E error * * message: "Versioning data not * * available for table: DBID,PSID, * * OBID". * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** .
Problem conclusion
Apply the PTF
Temporary fix
Comments
APAR Information
APAR number
PH22116
Reported component name
DB2 LOG ANALYSI
Reported component ID
5655E6601
Reported release
350
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-02-12
Closed date
2020-03-20
Last modified date
2020-04-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI68526
Modules/Macros
ALA#ERRM ALA#LCLF ALA#LDSN ALA#STOR ALA#WTO ALABHDR ALACLDEL ALADB2SP ALAFR1 ALAFR1CS ALAFR1CV ALAGEN1 ALAGEND ALALB2 ALALPD ALASETUP ALASUBG ALATSC ALATV ALATZC ALAUTIL ALAVBIO
Fix information
Fixed component name
DB2 LOG ANALYSI
Fixed component ID
5655E6601
Applicable component levels
R350 PSY UI68526
UP20/03/24 P F003
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.5.0"}]
Document Information
Modified date:
18 March 2021