IBM Support

PH21764: REPLICATION OF A TIMESTAMP WITH TIMEZONE COLUMN MAY PRODUCE DB2 MESSAGE DSNT408I WITH SQLCODE = -180

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When a source table contains a column with data type TIMESTAMP
    with timezone and when the transferable work is on the source
    datastore, the following SQL error may be issued on the target:
    DSNT408I SQLCODE = -180, ERROR:  THE DATE, TIME, OR TIMESTAMP
    VALUE *N IS INVALID
    

Local fix

  • No local fix available.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Infosphere Change Data Capture      *
    *                 for z/OS.                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: When a source table contains a column   *
    *                      with data type TIMESTAMP with timezone  *
    *                      and when the transferable work is on    *
    *                      the source datastore, the following     *
    *                      SQL error may be issued on the target:  *
    *                      DSNT408I SQLCODE = -180, ERROR:         *
    *                      THE DATE, TIME, OR TIMESTAMP VALUE *N   *
    *                      IS INVALID                              *
    ****************************************************************
    * RECOMMENDATION: APPLY CORRECTIVE SERVICE                     *
    ****************************************************************
    REPLICATION OF A TIMESTAMP WITH TIMEZONE COLUMN MAY PRODUCE DB2
    MESSAGE DSNT408I WITH SQLCODE = -180
    

Problem conclusion

  • MODULE CHCTDTGP WAS UPDATED TO FIX THE ISSUE.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH21764

  • Reported component name

    INFO SRVR CDC Z

  • Reported component ID

    5655U7600

  • Reported release

    A21

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-02-04

  • Closed date

    2020-02-13

  • Last modified date

    2020-03-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI67885

Modules/Macros

  •    CHCTDTGP CHCTMDDL
    

Fix information

  • Fixed component name

    INFO SRVR CDC Z

  • Fixed component ID

    5655U7600

Applicable component levels

  • RA21 PSY UI67885

       UP20/02/20 P F002

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: