IBM Support

PH21572: ENABLE STAND-ALONE PROCESSES OF IMS HP IMAGE COPY TO USE ENCRYPTED OSAM DATABASE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • Enable stand-alone processes of IMS HP Image Copy to use
    Encrypted OSAM database.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 2 users ( FMID=H1J0420 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR enables IMS High Performance  *
    *                      Image Copy to use encrypted OSAM        *
    *                      databases.                              *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR enables IMS High Performance Image Copy to use
    encrypted OSAM databases.
    
    This APAR enables IMS High Performance Image Copy to use
    encrypted OSAM databases.
    *********************
    ***** Important *****
    *********************
    - Dump process of Advanced Image Copy (FASTIC=(opt,DUMP)) can
      not use for encrypted OSAM database process
    - HASH Check and DB Sensor is not supported for encrypted OSAM
     Database.
    
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    The IBM IMS High Performance Image Copy for z/OS Version 4
    Release 2 User's Guide (SC19-2756-02)
    > Troubleshooting >> Messages and codes
    The following new messages have been added:
    
    FABJ313E VSAM ESDS DATA SET IS USED FOR OSAM OF DBD=dbdname
             DDN=ddname
    Explanation: VSAM ESDS data set is allocated for OSAM database.
                 ESDS is not allowed for OSAM database.
    System action: IMS HP Image Copy ends the job with return code
                   16.
    User response: Check the database data set. If you want to use
                   the OSAM encryption data set, you must use the
                   linear data set.
    
    FABJ0314E IMS LEVEL IS NOT HIGH ENOUGH TO SUPPORT VSAM LDS DATA
              SET OF OSAM  DBD= dbdname DDN=ddname
    Explanation: The IMS level does not support OSAM encryption.
    System action: IMS HP Image Copy ends the job with return code
                   16.
    User response: If you use encrypted OSAM, ensure IMS level of
                   runtime library.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH21572

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    420

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2020-01-29

  • Closed date

    2020-03-31

  • Last modified date

    2020-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI68712

Modules/Macros

  • FABJACQG FABJAPIM FABJASPM FABJATRC FABJCATS FABJCCAT FABJCMDB
    FABJCMP1 FABJCMP2 FABJCMP3 FABJCMP4 FABJCRC0 FABJCRC1 FABJCRC3
    FABJCTCV FABJCZCV FABJDALC FABJDALO FABJDALS FABJDBAL FABJDBC1
    FABJDBCM FABJDBD2 FABJDBD3 FABJDBD4 FABJDBD5 FABJDBD9 FABJDBDA
    FABJDBDB FABJDBF0 FABJDBLK FABJDBR2 FABJDBR3 FABJDBR4 FABJDBR5
    FABJDBR9 FABJDBRA FABJDBRB FABJDCTL FABJDDIM FABJDEMP FABJDFC2
    FABJDFC3 FABJDFC4 FABJDFC5 FABJDFC9 FABJDFCA FABJDFCB FABJDMP0
    FABJDMP2 FABJDMP3 FABJDMP4 FABJDMP5 FABJDMP9 FABJDMPA FABJDMPB
    FABJDOPN FABJDPS2 FABJDPS3 FABJDPS4 FABJDPS5 FABJDPS9 FABJDPSA
    FABJDPSB FABJDPUT FABJDREQ FABJDRQS FABJDRSN FABJFCAI FABJFCC2
    FABJFCC3 FABJFCC4 FABJFCC5 FABJFCC9 FABJFCCA FABJFCCB FABJFCCM
    FABJFCD2 FABJFCD3 FABJFCD4 FABJFCD5 FABJFCD9 FABJFCDA FABJFCDB
    FABJFDMP FABJGDGB FABJGLRP FABJICDD FABJIDX2 FABJIDX3 FABJIDX4
    FABJIDX5 FABJIDX9 FABJIDXA FABJIDXB FABJIGWI FABJINT1 FABJINT2
    FABJINT3 FABJIPRC FABJISDD FABJLINK FABJMAIN FABJMAS1 FABJMDP2
    FABJMDP3 FABJMDP4 FABJMDP5 FABJMDP9 FABJMDPA FABJMDPB FABJMRGE
    FABJMSGC FABJMSGP FABJMSUL FABJNTFC FABJNTFI FABJNTFS FABJOFDD
    FABJOFL0 FABJOFL1 FABJORC2 FABJORC3 FABJORC4 FABJORC5 FABJORC9
    FABJORCA FABJORCB FABJPARM FABJPRM2 FABJPRM3 FABJRCH2 FABJRCH3
    FABJRCH4 FABJRCH5 FABJRCH9 FABJRCHA FABJRCHB FABJRDB2 FABJRDB3
    FABJRDB4 FABJRDB5 FABJRDB9 FABJRDBA FABJRDBB FABJRETC FABJRETM
    FABJRFC2 FABJRFC3 FABJRFC4 FABJRFC5 FABJRFC9 FABJRFCA FABJRFCB
    FABJRPT0 FABJRPT1 FABJSAS1 FABJSAS2 FABJSDBK FABJSTA  FABJTERM
    FABJTFSI FABJTGEN FABJTGET FABJTOI  FABJTOI2 FABJTYPF FABJUIC1
    FABJWCRD FABJXCR  FABJXHPC FABJXLIM FABJZCP1 FABJZCP2 FABJZCP3
    FABJZCP4
    

Publications Referenced
SC19275602    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R420 PSY UI68712

       UP20/04/01 P F003

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89E","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0"}]

Document Information

Modified date:
10 April 2023