APAR status
Closed as program error.
Error description
Crash encountered when XML tag contains an invalid attribute (without space). For example : <dateOfBirthxsi:nil="true"/> instead of <dateOfBirth xsi:nil="true"/>
Local fix
ITXCQ - ITX00060032 GK / GK Circumvention: None
Problem summary
Users Affected: IBM Transformation Extender customers who use Xerces type tree XML parser, have restart set and are processing an invalid XML document. Problem Description: Crash in XML Parser. Stack trace: xml4c_5_8::SchemaValidator::checkContent() () from libxml4cTX.so.58 #1 xml4c_5_8::DstxXMLScanner::scanEndTag () at DstxXmlscanner.cpp:1301 #2 xml4c_5_8::DstxXMLScanner::scanContent () at DstxXmlscanner.cpp:1072 #3 xml4c_5_8::DstxXMLScanner::scanDocument () at DstxXmlscanner.cpp:334 #4 xml4c_5_8::DstxSAXParser::parse () at DstxSAXParser.cpp:561 Platforms Affected: All
Problem conclusion
Correct code to handle bad XML data when using Xerces type tree and when restart is set. Applies to: 9.0.0.4 10.0.0.0 10.0.3.0 Fixed in the next service packs and releases. To obtain the fix for this APAR: To see if the next service pack or product release is available, check the IBM Transformation Extender Release Notes page: https://www.ibm.com/support/docview.wss?uid=swg27008337 If the service pack or product release is available, download it from Fix Central: http://www.ibm.com/support/fixcentral/ If the service pack or product release is not available and you require the APAR fix immediately, request a Limited Availability Interim Fix (LAIF) by opening a case: https://www.ibm.com/mysupport/ Prior to version 9.0.0, IBM Transformation Extender was called IBM WebSphere Transformation Extender.
Temporary fix
Comments
APAR Information
APAR number
PH20843
Reported component name
ITX
Reported component ID
5724Q2300
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-01-10
Closed date
2020-02-20
Last modified date
2020-02-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITX
Fixed component ID
5724Q2300
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information