APAR status
Closed as program error.
Error description
IMS OM output user exit module can cause ABENDS0C1 or ABENDS0C6 when a lot of IMS commands are entered at the same time.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Sysplex manager. * **************************************************************** * PROBLEM DESCRIPTION: IMS OM output user exit module can * * cause ABENDS0C1 or ABENDS0C6 when a * * bunch of IMS commands are entered at * * the same time. * **************************************************************** * RECOMMENDATION: Apply the PTF that corrects this APAR. * **************************************************************** When a bunch of IMS commands are entered at the same time, IMS OM output user exit module, GJEOMOP0, can be called in parallel. If each GJEOMOP0 issues a BPE service call at the same time, the work area for BPE service call can be broken. This causes ABENDS0C1 or ABENDS0C6 in GJEOMOP0.
Problem conclusion
GJEOMIP0 and GJEOMOP0 has been changed not to share the work area for BPE service call.
Temporary fix
Comments
APAR Information
APAR number
PH20407
Reported component name
IMS SYSPLEX MGR
Reported component ID
5655P0100
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-12-17
Closed date
2020-01-29
Last modified date
2020-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI67617
Modules/Macros
GJEOMIP0 GJEOMOP0
Fix information
Fixed component name
IMS SYSPLEX MGR
Fixed component ID
5655P0100
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8AA","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.3.0"}]
Document Information
Modified date:
24 June 2022