A fix is available
APAR status
Closed as program error.
Error description
Statistics report long reports storage in 32k TS differently between V530 and V540 Account Trace long report shows invalid end time in identification header. With rollup records QWACESC is the accumulated elapsed time. This should be reported as N/P when Quantity greater than 0.
Local fix
apply ptf when available
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2 PM * * users of component * * - Batch Reporter * **************************************************************** * PROBLEM DESCRIPTION: 1. 'STORAGE IN 32K TS' value is * * different in STATISTICS REPORT * * for V530 and V540. * * 2. ACCOUNTING TRACE LONG * * report shows invalid 'END TIME' * * in identification header in case * * of rollup record. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** 1. Calculation for 'STORAGE IN 32K TS' was accidentally deactivated. Field used by the calculation process is valid in all supported DB2 versions. 2. Rollup flag was turned off so 'END TIME' value is invalid for rollup records.
Problem conclusion
1. Calculation for 'STORAGE IN 32K TS' has been activated. 2. Rollup flag is turned on for rollup record. 'END TIME' is set to 'N/P' for this one now. Search Keywords: STATISTICS TRACE STORAGE IN 32K TS ACCOUNTING TRACE ROLLUP END TIME IN IDENTIFICATION HEADER
Temporary fix
Comments
APAR Information
APAR number
PH19932
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
540
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-12-04
Closed date
2020-02-20
Last modified date
2020-03-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI68016
Modules/Macros
DGOACALC DGOSACUM
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R540 PSY UI68016
UP20/02/22 P F002
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
02 March 2020