Error description
The SYSPRINT DD statement in the JCL generated by MACRO DFSIDEF for the IEWL step for the type-4 SVC contains an extra comma after the SYSOUT=*. This causes a JCL error when running the job.
Local fix
Manually remove the comma from the generated JCL.
Problem summary
**************************************************************** * USERS AFFECTED: * * All IMS 15 users who use DFSIDEF to generate JCL for linking * * and binding SVC modules during System Generation. * **************************************************************** * PROBLEM DESCRIPTION: * * The SYSPRINT DD statement in the JCL generated by MACRO * * DFSIDEF for the IEWL step for the type-4 SVC contains an * * extra comma in the SYSPRINT statement after the SYSOUT=* * * parameter. This causes a JCL error when running the job. * **************************************************************** * RECOMMENDATION: * * INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** An installation can use the DFSIDEF macro with TYPE=GEN specified to generate JCL as output. The generated JCL can then be used to link and bind the SVC type 2 and type 4 modules during the System Generation process. The JCL generated for the type 4 module has an extraneous comma in the SYSPRINT statement, which causes a JCL error when the JCL is run.
Problem conclusion
DFSIDEF has been modified to remove the extraneous comma.
Temporary fix
Comments
APAR Information
APAR number
PH19197
Reported component name
IMS V15
Reported component ID
5635A0600
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-11-15
Closed date
2020-04-03
Last modified date
2020-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI68809
Modules/Macros
DFSIDEF
Fix information
Fixed component name
IMS V15
Fixed component ID
5635A0600
Applicable component levels
R500 PSY UI68809
UP20/04/07 P F004
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSEPH2","label":"IMS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"15","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
22 December 2023