IBM Support

PH19192: WAITTIME IS NOT PASSED TO BBOCLSCC UNDER CERTAIN CIRCMSTANCES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • There is a chance that WOLA inbound request triggered by CICS
    
    transaction reach BBOATRUE which in turn triggers BBOA1INV
    
    which holds variable WAITTIME. Under certain circumstances
    
    WAITTIME which is meant for BBOCLSCC is ignored. Consequently
    
    the CICS transaction stays in status *running* unless being
    
    manually kicked off
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of IBM WebSphere Application      *
    *                  Server V8.5 for z/OS                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: A BBOAINV request from CICS to a        *
    *                      WebSphere Application Server for        *
    *                      z/OS server hangs in BBOATRUE.          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When the WOLA connection pool is empty a BBOA1INV call from
    CICS can wait indefinitely for a new connection even when
    a non zero waittime is specified on the BBOA1INV call.
    The request can wait indefinitely because the waittime
    specified on the BBOA1INV call is not passed along properly.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH19192

  • Reported component name

    WEBSPHERE FOR Z

  • Reported component ID

    5655I3500

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-11-14

  • Closed date

    2019-12-11

  • Last modified date

    2019-12-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE FOR Z

  • Fixed component ID

    5655I3500

Applicable component levels

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS7K4U","label":"WebSphere Application Server for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"850","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
17 October 2021