IBM Support

PH18911: PROVIDE A NEW OPTION TO SELECT WHETHER TO DISPLAY THE DOCUMENT FIELDS IN THE PRF OPTION MODULES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • IMS Program Restart Facility currently displays the document
    fields (create date and user id) in the PRF option modules.
    This APAR addresses a requirement to allow users to control
    whether to display the document fields in the PRF option
    modules.
    This is enhancement is based off of RFE 84739.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IBM IMS Program Restart Facility for     *
    *                 z/OS Version 2 Release 2 (FMID=H23D220)      *
    *                 users.                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: Currently, IMS Program Restart Facility *
    *                      logs the creation date and the user id  *
    *                      in PRF options modules.                 *
    *                      This APAR addresses a requirement of    *
    *                      selecting whether to log the user id    *
    *                      in PRF options modules.                 *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This enhancement is being implemented as a result of RFE ID
    84739.
    Provide a new option AUDTOPMD to select whether to log the user
    id in PRF options modules.
    

Problem conclusion

Temporary fix

Comments

  • Provide a new option AUDTOPMD to select whether to log the user
    id in PRF options modules.
    
    ========================
    = Documentation Change =
    ========================
    IBM IMS Program Restart Facility for z/OS Version 2 Release 2
    User's Guide and Reference(SC19-3985-04) should be changed
    as follows:
    
    ================================================================
    > Product options reference
    >> Global options reference
    * A new option, AUDTOPMD, has been added as follows:
    ----------------------------------------------------------------
    ...
    |AUDTOPMD
    |
    | Information about updates in each IMS Program Restart Facility
    | options module is stored in the last record of each options
    | module in the following format:
    |
    |   Discriptor                Byte length
    |   Type of options module    8
    |   Reserved area             4
    |   Julian date (hexadecimal) 4
    |   Time (hexadecimal)        4
    |   User ID                   8
    |   Reserved area             variable length
    |
    | The AUDTOPMD option determines whether to log the user ID
    | information of the user who last updated each options module.
    | If you update the AUDTOPMD option, the user ID field of every
    | options module will be updated.
    |
    | AUDTOPMD=YES | NO
    |  YES
    |    If you specify YES, IMS Program Restart Facility logs the
    |    date and time when each options module was last updated
    |    and the user ID of the user who last updated it.
    |  NO
    |    If you specify NO, IMS Program Restart Facility does not
    |    log the user ID information.
    |
    |  The default value is YES.
    ...
    ----------------------------------------------------------------
    ================================================================
    > Troubleshooting
    >> ISPF messages (IRTA, IRTB, IRTC)
    * The following message has been changed: IRTB019E
    * The following messages have been added: IRTC112E, IRTC113W
    ----------------------------------------------------------------
    ...
    | IRTB019E Global Options Not Found
    |   Long message: options_module_name cannot be created until
    |                 Global Options have been created.
    |   System action: The request fails.
    |   User response: Ensure that global options are defined in
    |                  the IRTOPT data set before you define other
    |                  options.
    |
    | IRTC112E AUDTOPMD Option Invalid
    |   Long message: The AUDTOPMD value specified is not valid.
    |                 The value must be either YES or NO.
    |   System action: None.
    |   User response: Enter a valid value for the AUDTOPMD option.
    |
    | IRTC113W AUDTOPMD Process Skipped
    |   long message: Global Options have been saved. However, the
    |                 AUDTOPMD option processing is skipped because
    |                 another TSO user is currently editing other
    |                 options (options module xxxxxxxx).
    |   System action: None.
    |   User response: If you do not intend to change the AUDTOPMD
    |                  option, you can ignore this warning message.
    |                  If you want to change the AUDTOPMD option,
    |                  wait for the other TSO user to finish editing
    |                  the options, and then retry.
    ...
    ----------------------------------------------------------------
    ================================================================
    

APAR Information

  • APAR number

    PH18911

  • Reported component name

    IMS PGM RESTART

  • Reported component ID

    5655E1400

  • Reported release

    220

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2019-11-06

  • Closed date

    2019-12-12

  • Last modified date

    2020-01-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI66962

Modules/Macros

  • IRTB01   IRTC11   IRTINCL  IRTOPG0  IRTOPTA  IRTOPTJ  IRTOPTL
    IRTOPTR  IRTOPTW  IRTPRE10 IRTZF017 IRTZGETV IRTZINIT IRTZOPAE
    IRTZOPDE IRTZOPGE IRTZOPIE IRTZPUTV
    

Publications Referenced
SC19398504    

Fix information

  • Fixed component name

    IMS PGM RESTART

  • Fixed component ID

    5655E1400

Applicable component levels

  • R220 PSY UI66962

       UP19/12/13 P F912  

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVHR","label":"IMS Program Restart Facility for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: