Error description

  • An invalid EDI data file (HIPPA/X12) is not being detected by
    the IBM Transformation Extender Advanced Deenvelope Service. The
    processing of the invalid data shows success instead of the
    expected failure.
    
    This occurs when the segment identifier/tag is not present.
    

Local fix

  • ITXA: TS002913310 / github #20
    TR / TR
    Circumvention: None
    

Problem summary

  • Problem Description: Invalid HIPAA data
    returns "SUCCESS" status from ITXA service when WTX compliance
    check produces a "Rejected" status but with no reported errors.
    

Problem conclusion

  • Problem Conclusion: SPE parsed the WTX 999 for the compliance
    check operation but did not retain the transaction level codes
    reported by the AK5 and IK5 segments. This was not an oversight.
     SPE purposefully did not read these codes because the
    assumption was transaction level errors would be reported by
    running the transform map and the errors from the compliance
    check would be double-reported.
    
    However, in the customer case, there is no transform map.
    Therefore, no transaction level errors are reported.
    Subsequently, this leads to a false service report of SUCCESS
    and no error reporting for the bad transaction. The generated
    INT-1 999 acknowledgment is also not correct because it does not
    contain the IK5 segment.
    
    There are other errors exposed by this defect: The 999 specific
    transaction syntax error codes (e.g. I5) were not being parsed
    and reported properly in the SPE generated INT-1 999
    acknowledgment. The AK9 "E" (accepted with errors) status was
    not being reported properly in the
    InterchangeComplianceReport.xml document.
    
    The following fixes have been applied:
    1) Parse the WTX 999 for the transaction level error codes when
    creating the intermin compliance report.
    2) Fixed parsing of the 999-specific transaction syntax error
    codes and their respective mappings to the compliance report.
    3) When the WTX and SPE transaction compliance reports are
    merged check for duplicate error reporting and toss out the
    duplicates.
    
    Platforms Affected: All
    Customers Affected: Customers using WTX compliance checking for
    HIPAA where the inbound ST envelope does not use a
    transformation map and errors exist at the transaction level.
    Applies to: SPE.COMMON.9.0.2.0, SPE.COMMON.10.0.1.0
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH18893

  • Reported component name

    ITX ADV

  • Reported component ID

    5724Q2301

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-11-06

  • Closed date

    2020-05-27

  • Last modified date

    2020-05-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITX ADV

  • Fixed component ID

    5724Q2301

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDF7K","label":"IBM Transformation Extender Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
15 May 2022