A fix is available
APAR status
Closed as program error.
Error description
When you attempt to take image copies for both full-function databases and DEDBs with the HASH Check options in HPIC jobs, HPPC refers to incorrect storage area. That can cause ABEND0C4 in CSECT FABPHEXS at offset X'137C'. SYSTEM COMPLETION CODE=0C4 REASON CODE=00000011 DATA AT PSW 21C84376 - 408E4770 B396D501 4082E082
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IBM IMS High Performance Pointer Checker for * * z/OS Version 3 Release 1 (FMID=HPC2310) * * users who run HD Pointer Checker (HDPC) in * * IMS High Performance Image Copy (HPIC) jobs. * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 when taking image copies for * * both full-function databases and DEDBs * * with the HASH Check options in HPIC * * jobs. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When you take image copies for both full-function databases and DEDBs with the HASH Check options (HDPC=Y and DEDBPC=Y) in HPIC jobs, HD Pointer Checker refers to incorrect storage area. That can cause ABEND0C4 in CSECT FABPHEXS at offset X'137C'.
Problem conclusion
IMS HP Pointer Checker has been modified to fix the error.
Temporary fix
Comments
APAR Information
APAR number
PH18808
Reported component name
IMS POINTER CHE
Reported component ID
5655E0900
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-11-05
Closed date
2019-11-21
Last modified date
2019-11-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI66541
Modules/Macros
FABPHEXM FABPHEXS FABPHTRM
Fix information
Fixed component name
IMS POINTER CHE
Fixed component ID
5655E0900
Applicable component levels
R310 PSY UI66541
UP19/11/23 P F911
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89G","label":"IMS HP Pointer Checker"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: