IBM Support

PH17982: ABEND0C4 IN CPADISPC +X'5D0'.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Abend0c4 in module CPADISPC on a store instruction at + x'5D0'.
    General purpose register contains x'80000000' causing the abend.
                                                                   .
    The job involved is running with multiple SMF110 weekly
    datasets. It looks like in this case a full months worth of data
    is being processed, which is amounting to reading 70+ volumes.
    

Local fix

  • Workaround is to limit the number of SMF input files.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of CICS PA V5.4                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND0C4 in CPAMAIN +X'DB44'            *
    ****************************************************************
    ABEND0C4 occurs in CPAMAIN +X'DB44' when the number of records
    processed exceeds 2,147,483,647 due to record counter overflow.
    
    This APAR has been taken to ensure the record counter does not
    overflow. It does not increase the size of the record counter.
    After applying the APAR, if the record count for any record type
    exceeds 2,147,483,647 the number of records printed in the
    SYSPRINT file or that record type becomes unreliable.
    

Problem conclusion

  • CICS PA is changed to ensure that the record counter does not
    overflow and cause an abend.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH17982

  • Reported component name

    CICS PERF ANALY

  • Reported component ID

    5655Y2300

  • Reported release

    540

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-10-11

  • Closed date

    2019-11-04

  • Last modified date

    2019-11-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI66225

Modules/Macros

  • CPADISPC CPADSPFR
    

Fix information

  • Fixed component name

    CICS PERF ANALY

  • Fixed component ID

    5655Y2300

Applicable component levels

  • R540 PSY UI66225

       UP19/11/07 P F911

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPU4","label":"CICS Performance Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information