Error description
a Via header field in ACK requests might contain incorrect address in a dual stack environment
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Session Initiation Protocol (SIP) users of * * IBM WebSphere Application Server * **************************************************************** * PROBLEM DESCRIPTION: In a dual stack environment a Via * * header field in ACK requests might * * contain incorrect address. * **************************************************************** * RECOMMENDATION: * **************************************************************** In a dual stack environment a Via header field in ACK requests might contain incorrect address.
Problem conclusion
A fix was made in the SIP Container so a Via header field in ACK requests is set according to the preferred outbound interface setting. The following SIP Container custom property should be applied to activate the fix: Name: enable.set.outbound.interface Value: true The fix for this APAR is currently targeted for inclusion in fix pack 8.5.5.17 and 9.0.5.2. Please refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
Temporary fix
Comments
APAR Information
APAR number
PH15985
Reported component name
WEBS APP SERV N
Reported component ID
5724H8800
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-08-22
Closed date
2019-09-25
Last modified date
2019-09-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBS APP SERV N
Fixed component ID
5724H8800
Applicable component levels
R850 PSY
UP
R900 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
02 November 2021