A fix is available
APAR status
Closed as program error.
Error description
Message CHC9720E is issued when an error indication is returned from a system service. It should not be issued if the service indicated successful processing. CHC9720E is being issued for the "IARV64" service with return code 0, indicating successful processing. The logic associated with this service request should not be issuing this message if the request was successful. If the request failed, then the proper indications of such (return and reason codes) need to be provided in the CHC9720E message.
Local fix
None is available.
Problem summary
**************************************************************** * USERS AFFECTED: Users of IIDR CDC for z/OS who have migrated * * to z/OS V2R3. * **************************************************************** * PROBLEM DESCRIPTION: Users who have migrated to z/OS V2R3 * * may experience multiple issuances of * * message CHC9720E stating that an IARV64 * * service request has failed with a * * return code of 0. Subsequently various * * dumps may be written. * **************************************************************** * RECOMMENDATION: APPLY CORRECTIVE SERVICE * **************************************************************** Message CHC9720E may be issued stating that the IARV64 service failed with a return code of 0.
Problem conclusion
The return code from IARV64 will be tested properly.
Temporary fix
Comments
APAR Information
APAR number
PH15481
Reported component name
INFO SRVR CDC Z
Reported component ID
5655U7600
Reported release
A21
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-08-09
Closed date
2019-08-19
Last modified date
2019-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI64823
Modules/Macros
CHCGSSSW CHCMBARA CHCMBCHS CHCMBCHT CHCMBDAN CHCMBDES CHCMBDEU CHCMBELL CHCMBENG CHCMBENP CHCMBENU CHCMBESP CHCMBFIN CHCMBFRA CHCMBFRB CHCMBFRC CHCMBFRS CHCMBHEB CHCMBISL CHCMBITA CHCMBITS CHCMBJPN CHCMBKOR CHCMBNLB CHCMBNLD CHCMBNOR CHCMBPTB CHCMBPTG CHCMBRMS CHCMBRUS CHCMBSVE CHCMBTHA CHCMBTRK CHCMBZZZ CHCSMGSW
Fix information
Fixed component name
INFO SRVR CDC Z
Fixed component ID
5655U7600
Applicable component levels
RA21 PSY UI64823
UP19/08/27 P F908
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Edition":"","Line of Business":{"code":"","label":""}}]