Fixes are available
APAR status
Closed as program error.
Error description
At WAS 8.5.5.15, F servername,TRACEINIT displays: BBOO0427E TRIGGERED TRACE IS ENABLED WITH INCOMPLETE ENVIRONMENT VARIABLES. BBOO0211I MODIFY COMMAND TRACEINIT COMPLETED SUCCESSFULLY
Local fix
the command does complete ok - so the error can be ignored
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM WebSphere Application * * Server * * V8.5 * **************************************************************** * PROBLEM DESCRIPTION: WebSphere Application Server for z/OS * * processing a "f <server>,traceinit" * * command received an error message. * **************************************************************** * RECOMMENDATION: * **************************************************************** A control region processing a modify command for traceinit received the following error message: BBOO0427E TRIGGERED TRACE IS ENABLED WITH INCOMPLETE ENVIRONMENT VARIABLES. The error message was issued as a result of a missing check for the enablement of the triggered trace function.
Problem conclusion
Code has been modified in the traceinit command processing path to properly check for the enablement of the triggered trace serviceability function. The fix for this APAR is currently targeted for inclusion in fix packs 8.5.5.17 and 9.0.5.2. Please refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
Temporary fix
Comments
APAR Information
APAR number
PH15079
Reported component name
WEBSPHERE FOR Z
Reported component ID
5655I3500
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-07-30
Closed date
2019-08-14
Last modified date
2019-08-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE FOR Z
Fixed component ID
5655I3500
Applicable component levels
R850 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS7K4U","label":"WebSphere Application Server for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"850","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
17 October 2021