IBM Support

PH14611: ABEND0C4 HFPVBFI0 AT X'25C' RUNNING FPA RELOAD USING NON-IBM SORT UTILITY

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABENDS0C4 HFPVBFI0 at x'25C' when running Fast Path Advanced
    RELOAD utilizing non-IBM sort utility.                  S0C4
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of HPFPU Fast Path Advanced Tool   *
    *                 in Fast Path Solution Pack Version 1         *
    *                 Release 3 (FMID: HAHQ130).                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Fast Path Advanced Tool (FPA) RELOAD    *
    *                      function abended with S0C4 when using   *
    *                      non-IBM sort utility.                   *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    An unexpected value was set in access register when FPA SORT
    exit was called from the non-IBM sort utility, which caused the
    S0C4 abend.
    

Problem conclusion

  • FPA has been modified to save and clear all access registers
    before being called from an external program, and restore all
    access registers before returning to the external program.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH14611

  • Reported component name

    IMS FP SOLUTION

  • Reported component ID

    5655W1400

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-07-17

  • Closed date

    2019-08-14

  • Last modified date

    2022-09-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI64735

Modules/Macros

  • HFPA3000 HFPA3S00 HFPA4000 HFPAL000 HFPAMAN0 HFPAST40 HFPBFMN0
    HFPBLMN0 HFPBRDD5 HFPBRDDB HFPBRDDC HFPBRDDD HFPBRDDE HFPBRDM5
    HFPBRDMB HFPBRDMC HFPBRDMD HFPBRDME HFPBRDP0 HFPBRDS0 HFPBRDU0
    HFPBRDV0 HFPBRMN0 HFPDFAL0 HFPIIRM0 HFPQA2S0 HFPQA300 HFPQA400
    HFPQAIS0 HFPQARS0 HFPQASS0 HFPTDRC0 HFPTREX5 HFPTREXB HFPTREXC
    HFPTREXD HFPTREXE HFPTRIF0 HFPTRMN0 HFPTSRT0
    

Fix information

  • Fixed component name

    IMS FP SOLUTION

  • Fixed component ID

    5655W1400

Applicable component levels

  • R130 PSY UI64735

       UP19/08/16 P F908

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130"}]

Document Information

Modified date:
08 September 2022